SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Serruys Patrick W.) ;pers:(Gomez Lara Josep)"

Sökning: WFRF:(Serruys Patrick W.) > Gomez Lara Josep

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brugaletta, Salvatore, et al. (författare)
  • Morphology of coronary artery lesions assessed by virtual histology intravascular ultrasound tissue characterization and fractional flow reserve
  • 2012
  • Ingår i: The International Journal of Cardiovascular Imaging. - : Springer Science and Business Media LLC. - 1569-5794 .- 1875-8312 .- 1573-0743. ; 28:2, s. 221-228
  • Tidskriftsartikel (refereegranskat)abstract
    • Fractional flow reserve (FFR) is an index of the physiological significance of a coronary stenosis. Patients who have lesions with a FFR of >0.80, even optimally treated with medication, have however a MACE rate ranging from 8 to 21%. Coronary plaques at high risk of rupture and clinical events can be also identified by virtual histology intravascular ultrasound (IVUS-VH) as plaques with high amount of necrotic core (NC) abutting the lumen. Aim of this exploratory study was to investigate whether the geometry and composition of lesions with FFR ≤ 0.80 were different from their counterparts. Fifty-five consecutive patients in whom FFR was clinically indicated on a moderate angiographic lesion, received also an imaging investigation on the same lesion with IVUS-VH. Data on plaque geometry and composition was analyzed. Patients were subdivided in two groups according to the value of FFR (> or ≤0.80). Lesions with a FFR ≤ 0.80 (n = 17) showed a slightly larger plaque burden than those with FFR > 0.80 (n = 38) (54.6 ± 0.7% vs. 51.7 ± 0.7% P = 0.1). In addition, they tend to have less content of necrotic core than their counterparts (14.2 ± 8% vs. 19.2 ± 10.2%, P = 0.08). No difference was found in the distribution of NC-rich plaques (fibroatheroma and thin-capped fibroatheroma) between groups (82% in FFR ≤ 0.80 vs. 79% in FFR > 0.80, P = 0.5). Although FFR ≤ 0.80 lesions have larger plaque size, they do not differ in composition from the ones with FFR > 0.80. Further exploration in a large prospective study is needed to study whether the lesions with FFR > 0.80 that are NC rich are the ones associated with the presence of clinical events at follow-up.
  •  
2.
  • Sarno, Giovanna, et al. (författare)
  • Intravascular ultrasound radiofrequency analysis after optimal coronary stenting with initial quantitative coronary angiography guidance : an ATHEROREMO sub-study
  • 2011
  • Ingår i: EuroIntervention. - 1774-024X .- 1969-6213. ; 6:8, s. 977-984
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS:To investigate whether the use of intravascular ultrasound virtual histology (IVUS-VH) leads to any improvements in stent deployment, when performed in patients considered to have had an optimal percutaneous coronary intervention (PCI) by quantitative coronary angiography (QCA).METHODS AND RESULTS:After optimal PCI result (residual stenosis by QCA<30%), IVUS-VH was performed in 100 patients by protocol, with the option to use the information left to the discretion of the operators. Patients were categorised as: Group1 (n=54), where the IVUS-VH findings were used to evaluate the need for further optimisation of the stent deployment; and Group2 (n=46), where the IVUS-VH was documentary such that the stenting results were considered optimal according to QCA. Optimal stent deployment on IVUS-VH was defined as: normal stent expansion, absence of stent malapposition, complete lesion coverage as indicated by a plaque burden (PB%) between 30-40% and necrotic core confluent to the lumen<10% or PB%<30% at the 5 mm proximal and distal to the stent. The first IVUS-VH in all patients demonstrated the achievement of optimal stent deployment, incomplete lesion coverage, stent under-expansion and stent-edge dissection in 60%, 31%, 20% and 8% of patients, respectively. There was no stent malapposition. In Group 1, 25 patients had optimal stent deployment and did not require further intervention, whilst in 29 patients further intervention was needed (additional stent, n=18; post-dilatation, n=29). Overall optimal stent deployment was finally achieved in 52/54 patients (96%) in Group 1 and 35/46 (76%) of Group 2, p<0.05.CONCLUSIONS:IVUS-VH may have a role in facilitating optimal stent implantation and complete lesion coverage.
  •  
3.
  • Shen, Zhu Jun, et al. (författare)
  • Comparison of plaque prolapse in consecutive patients treated with Xience V and Taxus Liberte stents
  • 2012
  • Ingår i: The international journal of cardiovascular imaging. - : Springer Science and Business Media LLC. - 1875-8312 .- 1569-5794 .- 1573-0743. ; 28:1, s. 23-31
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this article is to investigate the prevalence of plaque prolapse (PP) after Xience V and Taxus Liberte stent implantation. During the study period 2006-2007, 200 consecutive patients underwent coronary revascularization for de novo lesions and received an intravascular ultrasound (IVUS) post-stenting evaluation, (n = 124 patients with Taxus Liberte and n = 76 with Xience V) (227 stent segments). Cross-sectional and longitudinal 3D IVUS images were analyzed in a blind fashion, evaluating the prevalence of PP and calculating its depth and angle. The angulation degree of the coronary artery at the lesion site pre-stent implantation was also evaluated by angiography. The prevalence of PP was 23.9% in Xience V versus 38.1% in Taxus Liberte (P = 0.025). The depth and angle of PP were greater in Taxus Liberte stent than Xience V stent (0.4 ± 0.1 mm versus 0.5 ± 0.2 mm, P = 0.004; and 32.0 ± 8.9° versus 44.6 ± 27.6°, P = 0.044, respectively). The angulation degree of the coronary artery at the lesion site was higher in presence of plaque prolapse than in its absence (48.2 ± 29.3° vs. 38.2 ± 28.1°, P = 0.013). By multivariate analysis, stent type was independently associated with incidence of plaque prolapse. Xience V stent has less plaque prolapse than Taxus Liberte stent. Stent design may play a role in the prevalence of plaque prolapse.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy