SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Shaw Leslie M) ;pers:(Umek Robert M)"

Sökning: WFRF:(Shaw Leslie M) > Umek Robert M

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Mattsson, Niklas, 1979, et al. (författare)
  • The Alzheimer's Association external quality control program for cerebrospinal fluid biomarkers.
  • 2011
  • Ingår i: Alzheimer's & dementia : the journal of the Alzheimer's Association. - : Wiley. - 1552-5279. ; 7:4, s. 386-395.e6
  • Tidskriftsartikel (refereegranskat)abstract
    • The cerebrospinal fluid (CSF) biomarkers amyloid β (Aβ)-42, total-tau (T-tau), and phosphorylated-tau (P-tau) demonstrate good diagnostic accuracy for Alzheimer's disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer's Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch-to-batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program.
  •  
2.
  • Mattsson, Niklas, 1979, et al. (författare)
  • Reference measurement procedures for Alzheimer's disease cerebrospinal fluid biomarkers: definitions and approaches with focus on amyloid β42.
  • 2012
  • Ingår i: Biomarkers in medicine. - : Future Medicine Ltd. - 1752-0371 .- 1752-0363. ; 6:4, s. 409-17
  • Tidskriftsartikel (refereegranskat)abstract
    • Cerebrospinal fluid (CSF) biomarkers for Alzheimer's disease (AD) are increasingly used in clinical settings, research and drug trials. However, their broad-scale use on different technology platforms is hampered by the lack of standardization at the level of sample handling, determination of concentrations of analytes and the absence of well-defined performance criteria for in vitro diagnostic or companion diagnostic assays, which influences the apparent concentration of the analytes measured and the subsequent interpretation of the data. There is a need for harmonization of CSF AD biomarker assays that can reliably, across centers, quantitate CSF biomarkers with high analytical precision, selectivity and stability over long time periods. In this position paper, we discuss reference procedures for the measurement of CSF AD biomarkers, especially amyloid β42 and tau. We describe possible technical approaches, focusing on a selected reaction monitoring mass spectrometry assay as a candidate reference method for quantification of CSF amyloid β42.
  •  
3.
  • Mollenhauer, Brit, et al. (författare)
  • Antibody-based methods for the measurement of α-synuclein concentration in human cerebrospinal fluid - method comparison and round robin study.
  • 2019
  • Ingår i: Journal of neurochemistry. - : Wiley. - 1471-4159 .- 0022-3042. ; 149:1, s. 126-138
  • Tidskriftsartikel (refereegranskat)abstract
    • α-Synuclein is the major component of Lewy bodies and a candidate biomarker for neurodegenerative diseases in which Lewy bodies are common, including Parkinson's disease and dementia with Lewy bodies. A large body of literature suggests that these disorders are characterized by reduced concentrations of α-synuclein in cerebrospinal fluid (CSF), with overlapping concentrations compared to healthy controls and variability across studies. Several reasons can account for this variability, including technical ones, such as inter-assay and inter-laboratory variation (reproducibility). We compared four immunochemical methods for the quantification of α-synuclein concentration in 50 unique CSF samples. All methods were designed to capture most of the existing α-synuclein forms in CSF ('total' α-synuclein). Each of the four methods showed high analytical precision, excellent correlation between laboratories (R2 0.83-0.99), and good correlation with each other (R2 0.64-0.93), although the slopes of the regression lines were different between the four immunoassays. The use of common reference CSF samples decreased the differences in α-synuclein concentration between detection methods and technologies. Pilot data on an immunoprecipitation mass spectrometry (IP-MS) method is also presented. Our results suggest that the four immunochemical methods and the IP-MS method measure similar forms of α-synuclein and that a common reference material would allow harmonization of results between immunoassays.
  •  
4.
  • Bjerke, Maria, 1977, et al. (författare)
  • Assessing the commutability of reference material formats for the harmonization of amyloid beta measurements.
  • 2016
  • Ingår i: Clinical chemistry and laboratory medicine : CCLM / FESCC. - : Walter de Gruyter GmbH. - 1437-4331 .- 1434-6621. ; 54:7, s. 1177-91
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The cerebrospinal fluid (CSF) amyloid-β (Aβ42) peptide is an important biomarker for Alzheimer's disease (AD). Variability in measured Aβ42 concentrations at different laboratories may be overcome by standardization and establishing traceability to a reference system. Candidate certified reference materials (CRMs) are validated herein for this purpose. METHODS: Commutability of 16 candidate CRM formats was assessed across five CSF Aβ42 immunoassays and one mass spectrometry (MS) method in a set of 48 individual clinical CSF samples. Promising candidate CRM formats (neat CSF and CSF spiked with Aβ42) were identified and subjected to validation across eight (Elecsys, EUROIMMUN, IBL, INNO-BIA AlzBio3, INNOTEST, MSD, Simoa, and Saladax) immunoassays and the MS method in 32 individual CSF samples. Commutability was evaluated by Passing-Bablok regression and the candidate CRM termed commutable when found within the prediction interval (PI). The relative distance to the regression line was assessed. RESULTS: The neat CSF candidate CRM format was commutable for almost all method comparisons, except for the Simoa/MSD, Simoa/MS and MS/IBL where it was found just outside the 95% PI. However, the neat CSF was found within 5% relative distance to the regression line for MS/IBL, between 5% and 10% for Simoa/MS and between 10% and 15% for Simoa/MSD comparisons. CONCLUSIONS: The neat CSF candidate CRM format was commutable for 33 of 36 method comparisons, only one comparison more than expected given the 95% PI acceptance limit. We conclude that the neat CSF candidate CRM can be used for value assignment of the kit calibrators for the different Aβ42 methods.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy