SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Suzuki S) srt2:(2010-2014);lar1:(ltu)"

Sökning: WFRF:(Suzuki S) > (2010-2014) > Luleå tekniska universitet

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Baron, P., et al. (författare)
  • The level 2 research product algorithms for the superconducting submillimeter-wave limb-emission sounder (SMILES)
  • 2011
  • Ingår i: Atmospheric Measurement Techniques Discussions. - : Copernicus GmbH. - 1867-8610. ; 4:3, s. 3593-3645
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper describes the algorithms of the level-2 research (L2r) processingchain developed for the Superconducting Submillimeter-Wave Limb-EmissionSounder (SMILES). The chain has been developed in parallel to the operationalchain for conducting researches on calibration and retrieval algorithms. L2rchain products are available to the scientific community. The objective ofversion 2 is the retrieval of the vertical distribution of trace gases in thealtitude range of 18-90 km. An theoretical error analysis is conducted toestimate the retrieval feasibility of key parameters of the processing:line-of-sight elevation tangent altitudes (or angles), temperature and O3 profiles. The line-of-sight tangent altitudes are retrievedbetween 20 and 50 km from the strong ozone (O3) line at 625.371 GHz,with low correlation with the O3 volume-mixing ratio and temperatureretrieved profiles. Neglecting the non-linearity of the radiometric gain inthe calibration procedure is the main systematic error. It is large for theretrieved temperature (between 5-10 K). Therefore, atmospheric pressure cannot be derived from the retrieved temperature, and, then, in the altituderange where the line-of-sight tangent altitudes are retrieved, the retrievedtrace gases profiles are found to be better represented on pressure levelsthan on altitude levels. The error analysis for the retrieved HOCl profiledemonstrates that best results for inverting weak lines can be obtained byusing narrow spectral windows. Future versions of the L2r algorithms willimprove the temperature/pressure retrievals and also provide information inthe upper tropospheric/lower stratospheric region (e.g., water vapor, icecontent, O3) and on stratospheric and mesospheric line-of-sight winds.
  •  
2.
  • Kasai, Y., et al. (författare)
  • Validation of stratospheric and mesospheric ozone observed by SMILES from International Space Station
  • 2013
  • Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 6:9, s. 2311-2338
  • Tidskriftsartikel (refereegranskat)abstract
    • We observed ozone (O3) in the vertical region between 250 and 0.0005 hPa (~ 12–96 km) using the Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES) on the Japanese Experiment Module (JEM) of the International Space Station (ISS) between 12 October 2009 and 21 April 2010. The new 4 K superconducting heterodyne receiver technology of SMILES allowed us to obtain a one order of magnitude better signal-to-noise ratio for the O3 line observation compared to past spaceborne microwave instruments. The non-sun-synchronous orbit of the ISS allowed us to observe O3 at various local times. We assessed the quality of the vertical profiles of O3 in the 100–0.001 hPa (~ 16–90 km) region for the SMILES NICT Level 2 product version 2.1.5. The evaluation is based on four components: error analysis; internal comparisons of observations targeting three different instrumental setups for the same O3 625.371 GHz transition; internal comparisons of two different retrieval algorithms; and external comparisons for various local times with ozonesonde, satellite and balloon observations (ENVISAT/MIPAS, SCISAT/ACE-FTS, Odin/OSIRIS, Odin/SMR, Aura/MLS, TELIS). SMILES O3 data have an estimated absolute accuracy of better than 0.3 ppmv (3%) with a vertical resolution of 3–4 km over the 60 to 8 hPa range. The random error for a single measurement is better than the estimated systematic error, being less than 1, 2, and 7%, in the 40–1, 80–0.1, and 100–0.004 hPa pressure regions, respectively. SMILES O3 abundance was 10–20% lower than all other satellite measurements at 8–0.1 hPa due to an error arising from uncertainties of the tangent point information and the gain calibration for the intensity of the spectrum. SMILES O3 from observation frequency Band-B had better accuracy than that from Band-A. A two month period is required to accumulate measurements covering 24 h in local time of O3 profile. However such a dataset can also contain variation due to dynamical, seasonal, and latitudinal effects
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy