NumreringReferensOmslagsbildHitta
1.
  • Albani, Giorgia, et al. (författare)
  • Evolution in boron-based GEM detectors for diffraction measurements : From planar to 3D converters
  • 2016
  • Ingår i: Measurement science and technology. - : IOP Publishing. - 0957-0233 .- 1361-6501. ; 27:11
  • Tidskriftsartikel (refereegranskat)abstract
    • The so-called '3He-crisis' has motivated the neutron detector community to undertake an intense R&D programme in order to develop technologies alternative to standard 3He tubes and suitable for neutron detection systems in future spallation sources such as the European spallation source (ESS). Boron-based GEM (gas electron multiplier) detectors are a promising '3He-free' technology for thermal neutron detection in neutron scattering experiments. In this paper the evolution of boron-based GEM detectors from planar to 3D converters with an application in diffraction measurements is presented. The use of 3D converters coupled with GEMs allows for an optimization of the detector performances. Three different detectors were used for diffraction measurements on the INES instrument at the ISIS spallation source. The performances of the GEM-detectors are compared with those of conventional 3He tubes installed on the INES instrument. The conceptual detector with the 3D converter used in this paper reached a count rate per unit area of about 25% relative to the currently installed 3He tube. Its timing resolution is similar and the signal-to-background ratio (S/B) is 2 times lower.
  •  
2.
  • Croci, Gabriele, et al. (författare)
  • A high-efficiency thermal neutron detector based on thin 3D (B4C)-B-10 converters for high-rate applications
  • 2018
  • Ingår i: Europhysics letters. - : IOP Publishing. - 0295-5075 .- 1286-4854. ; 123:5
  • Tidskriftsartikel (refereegranskat)abstract
    • new position-sensitive thermal neutron detector based on boron-coated converters has been developed as an alternative to today's standard He-3-based technology for application to thermal neutron scattering. The key element of the development is a novel 3D (B4C)-B-10 converter which has been ad hoc designed and realized with the aim of combining a high neutron conversion probability via the B-10(n, alpha)(7) Li reaction together with an efficient collection of the produced charged particles. The developed 3D converter is composed of thin aluminium grids made by a micro-waterjet technique and coated on both sides with a thin layer of( 10)B(4)C. When coupled to a GEM detector this converter allows reaching neutron detection efficiencies close to 50% at neutron wavelengths equal to 4 angstrom. In addition, the new detector features a spatial resolution of about 5 min and can sustain counting rates well in excess of 1 MHz/cm(2). The newly developed neutron detector will enable time-resolved measurements of different kind of samples in neutron scattering experiments at high flux spallation sources and can find a use in applications where large areas and custom geometries of thermal neutron detectors are foreseen. 
  •  
3.
  • Muraro, Andrea, et al. (författare)
  • Performance of the high-efficiency thermal neutron BAND-GEM detector
  • 2018
  • Ingår i: Progress of Theoretical and Experimental Physics. - : Oxford University Press (OUP). - 2050-3911. ; :2
  • Tidskriftsartikel (refereegranskat)abstract
    • Newhigh-count-rate detectors are required for future spallation neutron sources where large-area and high-efficiency (>50%) detectors are envisaged. In this framework, Gas Electron Multiplier (GEM) is one of the detector technologies being explored, since it features good spatial resolution (<0.5 cm) and timing properties, has excellent rate capability (MHz/mm(2)) and can cover large areas (some m(2)) at low cost. In the BAND-GEM (boron array neutron detector GEM) approach a 3D geometry for the neutron converter cathode was developed that is expected to provide an efficiency >30% in thewavelength range of interest for small angle neutron scattering instruments. A system of aluminum grids with thin walls coated with a 0.59 mu m layer of (B4C)-B-10 has been built and positioned in the first detector gap, orthogonally to the cathode. By tilting the grid system with respect to the beam, there is a significant increase of effective thickness of the borated material crossed by the neutrons. As a consequence, both interaction probability and detection efficiency are increased. This paper presents the results of the performance of the BAND-GEM detector in terms of efficiency and spatial resolution.
  •  