SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Volpe A) ;mspu:(researchreview)"

Sökning: WFRF:(Volpe A) > Forskningsöversikt

  • Resultat 1-10 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Schael, S., et al. (författare)
  • Electroweak measurements in electron positron collisions at W-boson-pair energies at LEP
  • 2013
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 532:4, s. 119-244
  • Forskningsöversikt (refereegranskat)abstract
    • Electroweak measurements performed with data taken at the electron positron collider LEP at CERN from 1995 to 2000 are reported. The combined data set considered in this report corresponds to a total luminosity of about 3 fb(-1) collected by the four LEP experiments ALEPH, DELPHI, 13 and OPAL, at centre-of-mass energies ranging from 130 GeV to 209 GeV. Combining the published results of the four LEP experiments, the measurements include total and differential cross-sections in photon-pair, fermion-pair and four-fermion production, the latter resulting from both double-resonant WW and ZZ production as well as singly resonant production. Total and differential cross-sections are measured precisely, providing a stringent test of the Standard Model at centre-of-mass energies never explored before in electron positron collisions. Final-state interaction effects in four-fermion production, such as those arising from colour reconnection and Bose Einstein correlations between the two W decay systems arising in WW production, are searched for and upper limits on the strength of possible effects are obtained. The data are used to determine fundamental properties of the W boson and the electroweak theory. Among others, the mass and width of the W boson, m(w) and Gamma(w), the branching fraction of W decays to hadrons, B(W -> had), and the trilinear gauge-boson self-couplings g(1)(Z), K-gamma and lambda(gamma), are determined to be: m(w) = 80.376 +/- 0.033 GeV Gamma(w) = 2.195 +/- 0.083 GeV B(W -> had) = 67.41 +/- 0.27% g(1)(Z) = 0.984(-0.020)(+0.018) K-gamma - 0.982 +/- 0.042 lambda(gamma) = 0.022 +/- 0.019. (C) 2013 Elsevier B.V. All rights reserved.
  •  
3.
  • Aamodt, K., et al. (författare)
  • The ALICE experiment at the CERN LHC
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:S08002
  • Forskningsöversikt (refereegranskat)abstract
    • ALICE (A Large Ion Collider Experiment) is a general-purpose, heavy-ion detector at the CERN LHC which focuses on QCD, the strong-interaction sector of the Standard Model. It is designed to address the physics of strongly interacting matter and the quark-gluon plasma at extreme values of energy density and temperature in nucleus-nucleus collisions. Besides running with Pb ions, the physics programme includes collisions with lighter ions, lower energy running and dedicated proton-nucleus runs. ALICE will also take data with proton beams at the top LHC energy to collect reference data for the heavy-ion programme and to address several QCD topics for which ALICE is complementary to the other LHC detectors. The ALICE detector has been built by a collaboration including currently over 1000 physicists and engineers from 105 Institutes in 30 countries, Its overall dimensions are 16 x 16 x 26 m(3) with a total weight of approximately 10 000 t. The experiment consists of 18 different detector systems each with its own specific technology choice and design constraints, driven both by the physics requirements and the experimental conditions expected at LHC. The most stringent design constraint is to cope with the extreme particle multiplicity anticipated in central Pb-Pb collisions. The different subsystems were optimized to provide high-momentum resolution as well as excellent Particle Identification (PID) over a broad range in momentum, up to the highest multiplicities predicted for LHC. This will allow for comprehensive studies of hadrons, electrons, muons, and photons produced in the collision of heavy nuclei. Most detector systems are scheduled to be installed and ready for data taking by mid-2008 when the LHC is scheduled to start operation, with the exception of parts of the Photon Spectrometer (PHOS), Transition Radiation Detector (TRD) and Electro Magnetic Calorimeter (EMCal). These detectors will be completed for the high-luminosity ion run expected in 2010. This paper describes in detail the detector components as installed for the first data taking in the summer of 2008.
  •  
4.
  • Abelev, B., et al. (författare)
  • Performance of the ALICE experiment at the CERN LHC
  • 2014
  • Ingår i: International Journal of Modern Physics A. - 0217-751X. ; 29:24
  • Forskningsöversikt (refereegranskat)abstract
    • ALICE is the heavy-ion experiment at the CERN Large Hadron Collider. The experiment continuously took data during the first physics campaign of the machine from fall 2009 until early 2013, using proton and lead-ion beams. In this paper we describe the running environment and the data handling procedures, and discuss the performance of the ALICE detectors and analysis methods for various physics observables.
  •  
5.
  • Aharonian, F., et al. (författare)
  • Simultaneous multiwavelength observations of the second exceptional gamma-ray flare of PKS2155-304 in July 2006
  • 2009
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 502:3, s. 749-770
  • Forskningsöversikt (refereegranskat)abstract
    • Aims. The X-ray-TeV connection and the evolution of the emitting particle population is studied in high-energy peaked BL Lac objects, by obtaining spectral information in both bands on sub-hour timescales. Methods. Simultaneous observations with HESS, Chandra and the Bronberg optical observatory were performed on the BL Lac object PKS 2155-304 in the night of July 29-30 2006, when the source underwent a major gamma-ray outburst during its high-activity state of Summer 2006. This event took place about 44 h after the other major outburst of the night of July 27-28, which is known for its ultrafast variability. An unprecedented 6 to 8 h of simultaneous, uninterrupted coverage was achieved, with spectra and light curves measured down to 7 and 2 min timescales, respectively. Results. The source exhibited one major flare along the night, at high energies. The gamma-ray flux reached a maximum of similar to 11 times the Crab flux (>400 GeV), with rise/decay timescales of similar to 1 h, plus a few smaller-amplitude flares superimposed on the decaying phase. The emission in the X-ray and VHE gamma-ray bands is strongly correlated, with no evidence of lags. The spectra also evolve with similar patterns, and are always soft ( photon index G > 2), indicating no strong shift of the peaks in the spectral energy distribution towards higher energies. Only at the flare maximum is there evidence that the gamma-ray peak is inside the observed passband, at similar to 400-600 GeV. The VHE spectrum shows a curvature that is variable with time and stronger at higher fluxes. The huge VHE variations (similar to 22x) are only accompanied by small-amplitude X-ray and optical variations (factor 2 and 15% respectively). The source has shown for the first time in a high-energy peaked BL Lac object a large Compton dominance (L(C)/L(S) similar to 10) - rapidly evolving - and a cubic relation between VHE and X-ray flux variations, during a decaying phase. These results challenge the common scenarios for the TeV-blazar emission.
  •  
6.
  • Grieser, M., et al. (författare)
  • Storage ring at HIE-ISOLDE Technical design report
  • 2012
  • Ingår i: The European Physical Journal Special Topics. - : Springer Science and Business Media LLC. - 1951-6355 .- 1951-6401. ; 207:1, s. 1-117
  • Forskningsöversikt (refereegranskat)abstract
    • We propose to install a storage ring at an ISOL-type radioactive beam facility for the first time. Specifically, we intend to setup the heavy-ion, low-energy ring TSR at the HIE-ISOLDE facility in CERN, Geneva. Such a facility will provide a capability for experiments with stored secondary beams that is unique in the world. The envisaged physics programme is rich and varied, spanning from investigations of nuclear ground-state properties and reaction studies of astrophysical relevance, to investigations with highly-charged ions and pure isomeric beams. The TSR might also be employed for removal of isobaric contaminants from stored ion beams and for systematic studies within the neutrino beam programme. In addition to experiments performed using beams recirculating within the ring, cooled beams can also be extracted and exploited by external spectrometers for high-precision measurements. The existing TSR, which is presently in operation at the Max-Planck Institute for Nuclear Physics in Heidelberg, is well-suited and can be employed for this purpose. The physics cases as well as technical details of the existing ring facility and of the beam and infrastructure requirements at HIE-ISOLDE are discussed in the present technical design report.
  •  
7.
  •  
8.
  • Lardas, Michael, et al. (författare)
  • Systematic Review of Surgical Management of Nonmetastatic Renal Cell Carcinoma with Vena Caval Thrombus
  • 2016
  • Ingår i: European Urology. - : Elsevier BV. - 0302-2838 .- 1873-7560. ; 70:2, s. 265-280
  • Forskningsöversikt (refereegranskat)abstract
    • CONTEXT: Overall, 4-10% of patients with renal cell carcinoma (RCC) present with venous tumour thrombus. It is uncertain which surgical technique is best for these patients. Appraisal of outcomes with differing techniques would guide practice.OBJECTIVE: To systematically review relevant literature comparing the outcomes of different surgical therapies and approaches in treating vena caval thrombus (VCT) from nonmetastatic RCC.EVIDENCE ACQUISITION: Relevant databases (Medline, Embase, and the Cochrane Library) were searched to identify relevant comparative studies. Risk of bias and confounding assessments were performed. A narrative synthesis of the evidence was presented.EVIDENCE SYNTHESIS: The literature search identified 824 articles. Fourteen studies reporting on 2262 patients were included. No distinct surgical method was superior for the excision of VCT, although the method appeared to be dependent on tumour thrombus level. Minimal access techniques appeared to have better perioperative and recovery outcomes than traditional median sternotomy, but the impact on oncologic outcomes is unknown. Preoperative renal artery embolisation did not offer any oncologic benefits and instead resulted in significantly worse perioperative and recovery outcomes, including possibly higher perioperative mortality. The comparison of cardiopulmonary bypass versus no cardiopulmonary bypass showed no differences in oncologic outcomes. Overall, there were high risks of bias and confounding.CONCLUSIONS: The evidence base, although derived from retrospective case series and complemented by expert opinion, suggests that patients with nonmetastatic RCC and VCT and acceptable performance status should be considered for surgical intervention. Despite a robust review, the findings were associated with uncertainty due to the poor quality of primary studies available. The most efficacious surgical technique remains unclear.PATIENT SUMMARY: We examined the literature on the benefits of surgery to remove kidney cancers that have spread to neighbouring veins. The results suggest such surgery, although challenging and associated with high risk of complications, appears to be feasible and effective and should be contemplated for suitable patients if possible; however, many uncertainties remain due to the poor quality of the data.
  •  
9.
  • Marconi, Lorenzo, et al. (författare)
  • Systematic Review and Meta-analysis of Diagnostic Accuracy of Percutaneous Renal Tumour Biopsy
  • 2016
  • Ingår i: European Urology. - : Elsevier. - 0302-2838 .- 1873-7560. ; 69:4, s. 660-673
  • Forskningsöversikt (refereegranskat)abstract
    • Context: The role of percutaneous renal tumour biopsy (RTB) remains controversial due to uncertainties regarding its diagnostic accuracy and safety.Objective: We performed a systematic review and meta-analysis to determine the safety and accuracy of percutaneous RTB for the diagnosis of malignancy, histologic tumour subtype, and grade.Evidence acquisition: Medline, Embase, and Cochrane Library were searched for studies providing data on diagnostic accuracy and complications of percutaneous core biopsy (CB) or fine-needle aspiration (FNA) of renal tumours. A meta-analysis was performed to obtain pooled estimates of sensitivity and specificity for diagnosis of malignancy. The Cohen kappa coefficient (κ) was estimated for the analysis of histotype/grade concordance between diagnosis on RTB and surgical specimen. Risk of bias assessment was performed (QUADAS-2).Evidence synthesis: A total of 57 studies recruiting 5228 patients were included. The overall median diagnostic rate of RTB was 92%. The sensitivity and specificity of diagnostic CBs and FNAs were 99.1% and 99.7%, and 93.2% and 89.8%, respectively. A good (κ = 0.683) and a fair (κ = 0.34) agreement were observed between histologic subtype and Fuhrman grade on RTB and surgical specimen, respectively. A very low rate of Clavien ≥2 complications was reported. Study limitations included selection and differential-verification bias.Conclusions: RTB is safe and has a high diagnostic yield in experienced centres. Both CB and FNA have good accuracy for the diagnosis of malignancy and histologic subtype, with better performance for CB. The accuracy for Fuhrman grade is fair. Overall, the quality of the evidence was moderate. Prospective cohort studies recruiting consecutive patients and using homogeneous reference standards are required.Patient summary: We systematically reviewed the literature to assess the safety and diagnostic performance of renal tumour biopsy (RTB). The results suggest that RTB has good accuracy in diagnosing renal cancer and its subtypes, and it appears to be safe. However, the quality of evidence was moderate, and better quality studies are required to provide a more definitive answer.
  •  
10.
  • Abu-Ghanem, Yasmin, et al. (författare)
  • Limitations of Available Studies Prevent Reliable Comparison Between Tumour Ablation and Partial Nephrectomy for Patients with Localised Renal Masses : A Systematic Review from the European Association of Urology Renal Cell Cancer Guideline Panel
  • 2020
  • Ingår i: European Urology Oncology. - : Elsevier. - 2588-9311. ; 3:4, s. 423-442
  • Forskningsöversikt (refereegranskat)abstract
    • The European Association of Urology (EAU) Renal Cell Carcinoma (RCC) Guideline Panel performed a protocol-driven systematic review (SR) on thermal ablation (TA) compared with partial nephrectomy (PN) for T1N0M0 renal masses, in order to provide evidence to support its recommendations. The Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines were followed, and only comparative studies published between 2000 and 2019 were included. Twenty-six nonrandomised comparative studies were included, recruiting a total of 167 80 patients. Risk of bias (RoB) assessment revealed high or uncertain RoB across all studies, with the vast majority being retrospective, observational studies with poorly matched controls and short follow-up. Limited data showed TA to be safe, but its long-term oncological effectiveness compared with PN remains uncertain. A quality assessment of pre-existing SRs (n = 11) on the topic, using AMSTAR, revealed that all SRs had low confidence rating, with all but two SRs being rated critically low. In conclusion, the current data are inadequate to make any strong and clear conclusions regarding the clinical effectiveness of TA for treating T1N0M0 renal masses compared with PN. Therefore, TA may be cautiously considered an alternative to PN for T1N0M0 renal masses, but patients must be counselled carefully regarding the prevailing uncertainties. We recommend specific steps to improve the evidence base based on robust primary and secondary studies.Patient summary: In this report, we looked at the literature to determine the effectiveness of thermoablation (TA) in the treatment of small kidney tumours compared with surgical removal. We found that TA could cautiously be offered as an option due to many remaining uncertainties regarding its effectiveness.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy