SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wiklund Urban) ;conttype:(scientificother)"

Sökning: WFRF:(Wiklund Urban) > Övrigt vetenskapligt/konstnärligt

  • Resultat 1-10 av 85
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abbaspour, Sara, 1984- (författare)
  • Proposing Combined Approaches to Remove ECG Artifacts from Surface EMG Signals
  • 2015
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Electromyography (EMG) is a tool routinely used for a variety of applications in a very large breadth of disciplines. However, this signal is inevitably contaminated by various artifacts originated from different sources. Electrical activity of heart muscles, electrocardiogram (ECG), is one of sources which affects the EMG signals due to the proximity of the collection sites to the heart and makes its analysis non-reliable. Different methods have been proposed to remove ECG artifacts from surface EMG signals; however, in spite of numerous attempts to eliminate or reduce this artifact, the problem of accurate and effective de-noising of EMG still remains a challenge. In this study common methods such as high pass filter (HPF), gating method, spike clipping, hybrid technique, template subtraction, independent component analysis (ICA), wavelet transform, wavelet-ICA, artificial neural network (ANN), and adaptive noise canceller (ANC) and adaptive neuro-fuzzy inference system (ANFIS) are used to remove ECG artifacts from surface EMG signals and their accuracy and effectiveness is investigated. HPF, gating method and spike clipping are fast; however they remove useful information from EMG signals. Hybrid technique and ANC are time consuming. Template subtraction requires predetermined QRS pattern. Using wavelet transform some artifacts remain in the original signal and part of the desired signal is removed. ICA requires multi-channel signals. Wavelet-ICA approach does not require multi-channel signals; however, it is user-dependent. ANN and ANFIS have good performance, but it is possible to improve their results by combining them with other techniques. For some applications of EMG signals such as rehabilitation, motion control and motion prediction, the quality of EMG signals is very important. Furthermore, the artifact removal methods need to be online and automatic. Hence, efficient methods such as ANN-wavelet, adaptive subtraction and automated wavelet-ICA are proposed to effectively eliminate ECG artifacts from surface EMG signals. To compare the results of the investigated methods and the proposed methods in this study, clean EMG signals from biceps and deltoid muscles and ECG artifacts from pectoralis major muscle are recorded from five healthy subjects to create 10 channels of contaminated EMG signals by adding the recorded ECG artifacts to the clean EMG signals. The artifact removal methods are also applied to the 10 channels of real contaminated EMG signals from pectoralis major muscle of the left side. Evaluation criteria such as signal to noise ratio, relative error, correlation coefficient, elapsed time and power spectrum density are used to evaluate the performance of the proposed methods. It is found that the performance of the proposed ANN-wavelet method is superior to the other methods with a signal to noise ratio, relative error and correlation coefficient of 15.53, 0.01 and 0.98 respectively.
  •  
2.
  • Aiso, Toshiharu, 1983- (författare)
  • Workpiece steels protecting cutting tools from wear : A study of the effects of alloying elements on material transfer and coating damage mechanisms
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The vision of this thesis is to improve the machinability of workpiece steels. Workpiece material frequently transfers to the cutting tools during machining, and the transfer layers then forming on the tools may give both good and bad effects on machining performance and tool life. The objective of this work is to understand the effects of alloying element additions to workpiece steels on material transfer and the roles of the formed transfer layers on friction characteristics and wear of tools.To isolate and study the influence of the individual alloying elements, model steels are specifically designed. These steels include one reference with C as the only alloying element and others alloyed also with single additions or combined additions of 1 mass% Si, Mn, Cr and Al. The experiments are performed using both a sliding test, simulating the material transfer in milling, and a turning test.In a sliding contact, the mode of transfer is strongly dependent on the normal load and sliding speed. Material transfer initiates extremely fast, in less than 0.025 s, and characteristic transfer layers develop during the first few seconds. The different steel compositions result in the formation of different types of oxides in the transfer layers. At the workpiece/tool interface where the conditions involve high temperature, high pressure and low oxygen supply, easily oxidized alloying elements in the steel are preferentially transferred, enriched and form a stable oxide on the tool surface. The degree of enrichment of the alloying elements in the oxides is strongly related to their tendencies to become oxidized.The difference in melting temperature of the oxides, and thus the tendency to soften during sliding, explains the difference in the resulting friction coefficient. The widest differences in friction coefficients are found between the Si and Al additions. A Si containing oxide shows the lowest friction and an Al containing oxide the highest.The damage mechanism of coated tools is chiefly influenced by the form and shear strength of the transferred material. Absence of transfer layer or non-continuous transferred material leads to continuous wear of the coating. Contrastingly, continuous transfer layers protect it from wear. However, transfer layers with very high shear strength result in high friction heat and a large amount of steel transfer. This leads to rapid coating cracking or adhesive wear.
  •  
3.
  • Alenius Dahlqvist, Jenny, 1972- (författare)
  • Heart rate variability and pacemaker treatment in children with Fontan circulation
  • 2019
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Background: Fontan surgery is performed in children with univentricular heart defects. Arrhythmias are frequent complications, occasionally requiring pacemaker treatment. Previous data regarding indications and risk factors for pacemaker treatment in Fontan patients is limited and conflicting. Heart rate variability (HRV) reflects autonomous nervous activity controlling the sinus node and has been associated with tachyarrhythmias in both adults and children, as well as in adults with sinus node dysfunction (SND).Aim: To study HRV, arrhythmia and pacemaker treatment  in children with Fontan circulation— with the purpose of contributing to the reduction of long term complications in this patient group.Methods: We have retrospectively reviewed pacemaker therapy in all Swedish patients who underwent Fontan surgery from 1982 to 2017 (n=599). We have also analysed HRV from 24-hour Holter ECG recordings in 112 children with Fontan circulation and in children with univentricular heart defects before bidirectional Glenn (BDG) procedure (n=47), before and on completion of Fontan surgery (n=47 and 45 respectively). Analysis was performed by power spectral analysis and Poincaré method, and results compared with healthy controls. Furthermore, HRV was analysed in Fontan patients who later required a pacemaker due to severe SND. Results were compared with Fontan patients who had SND, without indication for pacemaker treatment, with patients with Fontan circulation without SND and healthy controls. In addition we evaluated the possibility to analyse arrhythmias and HRV in 27 Fontan children using intermittent ECG recordings with a handheld devices at home during a 14-day period.Results: After a mean follow-up of 12 years, 13% (78/599) of patients with Fontan circulation had received a pacemaker. Patients operated with the extracardiac conduit (EC) had a significantly lower prevalence of pacemaker implantation (6%) than patients with a lateral tunnel (LT) (17%). The most common pacemaker indication in patients with Fontan circulation was SND (64%). Children with Fontan circulation showed significant reductions in several HRV parameters, compared with controls. No significant differences were found between patients operated with LT versus EC (paper I). After BDG the RR interval and SD2 (representing changes in heart rate over 24-hours) significantly increased compared to pre-BDG. Compared with healthy controls, patients post-BDG, had significantly longer RR intervals and reduced overall HRV. PHF (reflecting parasympathetic control of the heart) was significantly reduced after TCPC as compared to before (paper II). Fontan patients with SND showed significantly elevated SD2 (representing changes in heart rate over 24-hours), somewhat reduced in patients that later required a pacemaker (Paper V). Handheld ECG analysis revealed frequent ventricular extra systoles in one patient and episodes of supraventricular tachycardia in another. Seven Fontan patients showed reduced HRV recorded with the handheld device over a 14-day period (paper III).Conclusions: Overall HRV was reduced in patients with univentricular heart defects during the different surgical stages of Fontan surgery, compared to healthy controls. HRV was reduced in both patients with LT and EC with no significant difference between them. After BDG heart rate was significantly reduced as compared to before. PHF, reflecting the parasympathetic innervation of the heart was reduced after as compared to before TCPC. Pacemaker treatment is commonly needed in patients with Fontan circulation, and SND was the most prevalent indication for implantation. The prevalence of Fontan patients requiring pacemaker treatment was significantly lower in patients with EC. HRV analysis can contribute to management when following-up patients with Fontan circulation.  
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • André, Benny (författare)
  • Nanocomposites for Use in Sliding Electrical Contacts
  • 2011
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • In this thesis nanocomposite materials for use in high performance electrical contacts are tested. Self mating silver as coatings on cupper substrates are the most used material combination in power connectors today. In this work two new concepts were tested. The first one was to change one of the mating surfaces to a hard thin coating and keep the other surface made of silver. Tested coatings were nanocomposites with hard carbides in a matrix of amorphous carbon. TiC/a-C and  Ti-Ni-C/a-C were tested both electrically and tribologically. The total amount of carbon and the amount of carbon matrix was important, both for the electrical and the tribological properties. The Ti-Ni-C coating also showed that substituting Ti in TiC with the weak carbide former Ni changed the stability of the carbides. The substitution resulted in more a-C matrix and less C in the carbides. Thin coatings of nc-TiC/a-C and  Ti-Ni-C/a-C showed high potential as material candidates for use in electrical contacts. The other tested concept was to modify the used silver instead of replacing it. This was done by embedding nanoparticles of solid lubricant IF-WS2 in the silver. The results from reciprocating sliding displayed low friction and high wear resistance. The modified silver surfaces lasted for 8000 strokes with a friction of about 0.3 while at the same time allowing for a low contact resistance. The results for surfaces of pure silver coating displayed a friction of 0.8-1.2 and that the silver was worn through already after 300 strokes. A new method to investigate inherent hardness and residual stress of thin coatings, on complex geometries or in small areas, was also developed. An ion beam was used to create stress free coating as free standing micro pillars. Hardness measured on the pillars and on as-deposited coating were then used to calculate the residual stress in the coatings.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 85
Typ av publikation
annan publikation (27)
doktorsavhandling (24)
konferensbidrag (14)
tidskriftsartikel (13)
rapport (4)
licentiatavhandling (3)
visa fler...
visa färre...
Typ av innehåll
Författare/redaktör
Wiklund, Urban (64)
Wiklund, Urban, Prof ... (9)
Hogmark, Sture (9)
Heldin, Magnus (9)
Suhr, Ole B. (5)
Karlsson, Marcus (5)
visa fler...
Rydberg, Annika (4)
Nilsson, Daniel (4)
Gueret, P (4)
Jacobson, Staffan (4)
Nicoll, Rachel (4)
Stavlid, Nils (4)
Wiklund, Urban, Doce ... (3)
Eriksson, J W (3)
Jacobson, Staffan, P ... (3)
Hörnsten, Rolf (3)
Eliasson, Håkan (3)
André, Benny (3)
Lindquist, Mattias (3)
Henein, Michael (3)
Olofsson, Bert-Ove (3)
Jacobson, Staffan, P ... (3)
Heinrichs, Jannica (3)
Henein, Michael Y. (2)
Holmberg, Anders (2)
Lundbäck, Andreas (2)
Alenius Dahlqvist, J ... (2)
Rydberg, Annika, Pro ... (2)
Abrahamsson, N. (2)
Lundqvist, M. H. (2)
Hammar, U. (2)
Sundbom, M. (2)
Pereira, M. J. (2)
Andersson, Carl (2)
Kassman Rudolphi, Ås ... (2)
Wiklund, Mats (2)
Fisk, Martin (2)
Hektor, Johan (2)
Guo, Li (2)
Sandsjö, Leif (2)
Jensen, Steen M. (2)
Berglin, Lena (2)
Granåsen, Gabriel, 1 ... (2)
Björketun, Urban (2)
Granåsen, Gabriel (2)
Isaksson, Per (2)
Carlsson, Jenny, 198 ... (2)
Heinrichs, Jannica, ... (2)
Erelund, Sofia, 1983 ... (2)
Gerth, Julia (2)
visa färre...
Lärosäte
Uppsala universitet (43)
Umeå universitet (29)
Luleå tekniska universitet (4)
Linköpings universitet (2)
Högskolan i Borås (2)
VTI - Statens väg- och transportforskningsinstitut (2)
visa fler...
Stockholms universitet (1)
Mälardalens universitet (1)
Mittuniversitetet (1)
Högskolan Dalarna (1)
visa färre...
Språk
Engelska (75)
Odefinierat språk (7)
Svenska (3)
Forskningsämne (UKÄ/SCB)
Teknik (37)
Medicin och hälsovetenskap (25)
Naturvetenskap (3)
Lantbruksvetenskap (1)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy