SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Yang Li xin)
 

Sökning: WFRF:(Yang Li xin) > Mälardalens universitet > Alternative positio...

Alternative positions of internal heat exchanger for CO2 booster refrigeration system : Thermodynamic analysis and annual thermal performance evaluation

Liu, Shengchun (författare)
Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin, Peoples R China.;UNiLAB Integrated Syst Anal Tools, Singapore, Singapore.
Wang, Jiahao (författare)
Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin, Peoples R China.
Dai, Baomin (författare)
Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin, Peoples R China.
visa fler...
Yang, Xin (författare)
Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin, Peoples R China.
Nian, Victor (författare)
Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin, Peoples R China.;UNiLAB Integrated Syst Anal Tools, Singapore, Singapore.;Natl Univ Singapore, Energy Studies Inst, Singapore, Singapore.
Li, Hailong, 1976- (författare)
Mälardalens universitet,Framtidens energi,UNiLAB Integrated Syst Anal Tools, Singapore, Singapore
Yuan, Jun (författare)
UNiLAB Integrated Syst Anal Tools, Singapore, Singapore.;Shanghai Maritime Univ, China Inst FTZ Supply Chain, Shanghai, Peoples R China.
visa färre...
Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin, Peoples R China;UNiLAB Integrated Syst Anal Tools, Singapore, Singapore. Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin, Peoples R China. (creator_code:org_t)
ELSEVIER SCI LTD, 2021
2021
Engelska.
Ingår i: International journal of refrigeration. - : ELSEVIER SCI LTD. - 0140-7007 .- 1879-2081. ; 131, s. 1016-1028
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Refrigeration systems running on transcritical CO2 cycle are considered an alternative to phase-down the use of hydrofluorocarbons (HFCs) in response to the Kigali Amendment. Responding to the need to improve the efficiency of CO2 booster systems and to identify optimum system designs, thermodynamic models of three booster systems are proposed with the use of an internal heat exchanger (IHX). Findings from this study suggest that placing the IHX with a low-temperature fluid side at the suction line of high pressure stage compressor and high-temperature fluid side at the outlet of gas cooler represents the most optimal approach in improving the coefficient of performance (COP) of the booster system. When operating in the transcritical conditions, the COP values can be improved by 6.35% at the IHX thermal effectiveness of 0.8 and by 6.48% at the ratio of medium temperature load to low temperature load of 6. Using IHX can significantly reduce the compressor discharge pressure, which can be reduced by 0.55 MPa at the ambient temperature of 40 degrees C. Furthermore, by adding IHX, the annual performance factor of CO2 system can be improved significantly by 1.68% and the annual total power consumption can be decreased by 6.48% in the tropical climate. It can be concluded that IHX can improve the COP values of a booster system when operating in the subtropical and tropical regions. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

CO2
Booster system
Internal heat exchanger
Thermodynamic analysis
Annual thermal performance
Optimal configuration

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy