SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zhang He) ;lar1:(mdh)"

Sökning: WFRF:(Zhang He) > Mälardalens universitet

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Campana, Pietro Elia, 1984-, et al. (författare)
  • A gridded optimization model for photovoltaic applications
  • 2020
  • Ingår i: Solar Energy. - : PERGAMON-ELSEVIER SCIENCE LTD. - 0038-092X .- 1471-1257. ; 202, s. 465-484
  • Tidskriftsartikel (refereegranskat)abstract
    • This study aims to develop a gridded optimization model for studying photovoltaic applications in Nordic countries. The model uses the spatial and temporal data generated by the mesoscale models STRANG and MESAN developed by the Swedish Meteorological and Hydrological Institute. The model is developed based on the comparison between five irradiance databases, three decomposition models, two transposition models, and two photovoltaic models. Several techno-economic and environmental aspects of photovoltaic systems and photovoltaic systems integrated with batteries are investigated from a spatial perspective. CM SAF SARAH-2, Engerer2, and Perez1990 have shown the best performances among the irradiance databases, and decomposition and transposition models, respectively. STRANG resulted in the second-best irradiance database to be used in Sweden for photovoltaic applications when comparing hourly global horizontal irradiance with weather station data. The developed model can be employed for carrying out further detailed gridded techno-economic assessments of photovoltaic applications and energy systems in general in Nordic countries. The model structure is generic and can be applied to every gridded climatological database worldwide.
  •  
2.
  • He, W., et al. (författare)
  • Optimal Thermal Management Of Server Cooling System Based Cooling Tower Under Different Ambient Temperatures
  • 2022
  • Ingår i: Applied Thermal Engineering. - : Elsevier Ltd. - 1359-4311 .- 1873-5606. ; 207
  • Tidskriftsartikel (refereegranskat)abstract
    • To develop a highly efficient and energy-saving cooling system in a data center, this study investigates the optimal thermal management both on the internal server cooling cycle and external cold source water cycle under different ambient temperatures based on the principle of minimal power consumption. Taking a server cabinet of 4.8 kW as the case, an internal indirect water-cooled heat sink cycle and an external cooling tower cold source cycle are constructed. A hybrid thermal management model combined with a heat dissipation model and a power consumption model was developed with the aid of MATLAB and TRNSYS. Using this model, the relationship between the chip dissipation performance attached to the fin-type heat sink and the energy consumption performance of the cooling system under different water working conditions and ambient temperatures was analyzed. Finally, to achieve minimal system energy consumption, the optimized inlet temperature and water flow rates corresponding to different ambient temperatures were obtained by fitting expressions that can better serve the optimal design of data center cooling systems. Furthermore, when the optimal value was applied using the year-round temperature of Tianjin, China in the case study, a 21.3% reduction in power consumption and a 4.43% decrease in the power usage effectiveness can be achieved compared to the case without optimization. Therefore, significant power can be saved in a data center cooling system through thermal management optimization. 
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy