SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zhang Qiang) ;spr:chi"

Sökning: WFRF:(Zhang Qiang) > Kinesiska

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Qian, Li-Bing, et al. (författare)
  • Transmission of electrons through the conical glass capillary with the grounded conducting outer surface
  • 2017
  • Ingår i: Wuli xuebao. - : Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences. - 1000-3290. ; 66:12
  • Tidskriftsartikel (refereegranskat)abstract
    • The transmission of 1.5 keV-electrons through a conical glass capillary is reported. This study aims to understand the so-called guiding effect for the negatively charged particles (e.g. electrons). The guiding mechanism is understood quite well with positively charged particles in particular highly charged ions, but not clear with electrons, i. e., even the basic scheme mediated by the existence of negative charge patches to guide the electrons is still somewhat controversial.. The study of the charging-up dynamics causing the electrons transport inside the capillary will shed light on this issue. In order to perform this, a data acquisition system has been setup to follow the time evolution of the two-dimensional angular distribution of the transmitted electrons. The electrons are detected by the multi-channel plate (MCP) detector with a phosphor screen. The image from the phosphor screen is recorded by a charge-coupled device camera. The timing signals for the detected events are extracted from the back stack of the MCP detector and recorded by the data acquisition system, synchronized with the acquired images. The electron beam has a size of 0.5 mm x 0.5 mm and a divergence of less than 0.35.. The inner diameter of the straight part of the capillary is 1.2 mm and the exit diameter is 225 mu m. A small conducting aperture of 0.3 mm in diameter is placed at the entrance of the capillary. Two-dimensional angular distribution of the transmitted electrons through conical glass capillary and its time evolution are measured. The results show that the transmission rate decreases and reaches to a constant value for the completely discharged glass capillary with time going by. The centroid of the angular distribution moves to an asymptotic value while the width remains unchanged. These transmission characteristics are different from those indicated in our previous work (2016 Acta Phys: Si n: 65 204103). The difference originates from the different manipulations of the capillary outer surface. A conducting layer is coated on the outer surface of the capillary and grounded in this work. This isolates various discharge/charge channels and forms a new stable discharge channel. The transmission rate as a function of the tilt angle shows that the allowed transmission occurs at the tilt angle limited by the geometrical factors, i. e., the geometrical opening angle given by the aspect ratio as well as the beam divergence. The transmission characteristics suggest that most likely there are formed no negative patches to facilitate the electron transmission through the glass capillary at this selected beam energy. It is different from that of highly charged ions, where the formation of the charge patches prohibits the close collisions between the following ions and guides them out of the capillary.
  •  
2.
  • Wan, Cheng-Liang, et al. (författare)
  • Dynamics of slow electrons transmitting through straight glass capillary and tapered glass capillary
  • 2016
  • Ingår i: Wuli xuebao. - : Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences. - 1000-3290. ; 65:20
  • Tidskriftsartikel (refereegranskat)abstract
    • It has been found that the transmission rate of the electrons through insulating capillaries as a function of time/incident charge is not the same as that of the ions. The question arises that by using the electrons, if the negative charge patches can be formed to facilitate the transmission of the following electrons, thereby substantiating that the so-called guiding effect works also for electrons. This study aims to observe the time evolutions of the transmission of electrons through a straight glass tube and a tapered glass capillary. This will reveal the details of how and (or) if the negative charge patches can be formed when the electrons transport through them. In this work, a set of MCP/phosphor two-dimensional detection system based on Labview platform is developed to obtain the time evolution of the angular distribution of the transmitted electrons. The pulsed electron beams are obtained to test our detection system. The time evolution of the angular profile of 1.5 keV electrons transmitting through the glass tube/capillary is observed. The transmitted electrons are observed on the detector for a very short time and disappear for a time and then appear again for both the glass tube and tapered glass capillary, leading to an oscillation. The positive charge patches are formed in the insulating glass tube and tapered glass capillary since the secondary electron emission coefficient for the incident energy is larger than 1. It is due to the fact that fast discharge of the deposited charge leads to the increase of the transmission rate, while the fast blocking of the incident electrons due to the deposited positive charge leads to the decrease of the transmission rate. The geometrical configuration of the taper glass capillary tends to make the secondary electrons deposited at the exit part to form the negative patches that facilitate the transmission of electrons. This suggests that if the stable transmission needs to be reached for producing the electron micro-beam by using tapered glass capillaries, the steps must be taken to have the proper grounding and shielding of the glass capillaries and tubes. Our results show a difference in transmission through the insulating capillary between electrons and highly charged ions.
  •  
3.
  •  
4.
  • Han, Lei, et al. (författare)
  • 基于飞秒激光的一维速度场测量方法
  • 2022
  • Ingår i: Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics. - 0253-231X. ; 43:1, s. 267-271
  • Tidskriftsartikel (refereegranskat)abstract
    • Femtosecond laser-induced cyano chemiluminescence uses femtosecond filaments to tag molecules in a flow field, and velocity information of the flow field can be obtained by observing the displacement of the tagged molecules within a known time. The one-dimensional (1D) emitting line contains 1D velocity field information, but only the velocity at the central point can be given because it is unable to precisely correlate the position information before and after the line moves. For this problem, we propose a 1D velocity field inversion algorithm, which can invert the velocity of the whole emitting line according to the displacement of the emitting line and its shape, and finally obtain the 1D-2C velocity field information on the line. By using the moving trajectory of multiple emitting lines we can also obtain the 2D velocity field information.
  •  
5.
  • Li, Xiaofeng, et al. (författare)
  • 双色光束增强飞秒激光氮气标记示踪测速技术的研究
  • 2022
  • Ingår i: Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics. - 0253-231X. ; 43:10, s. 2826-2830
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work, the fluorescence of FLEET (femtosecond laser electron excited tagging) was enhanced by two color femtosecond laser. the intensity of FLEET was increased about 20% with two laser pulses that were 400 μJ/pulse at 266 nm and 3 mJ/pulse at 800 nm, and the results indicated that there was nearly no influence on lifetime and wavelength of fluorescence from FLEET. This result provides many information for the following studies.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy