1. |
- Bustin, Stephen A., et al.
(författare)
-
The need for transparency and good practices in the qPCR literature
- 2013
-
Ingår i: Nature Methods. - : Springer Science and Business Media LLC. - 1548-7091 .- 1548-7105. ; 10:11, s. 1063-1067
-
Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
- Two surveys of over 1,700 publications whose authors use quantitative real-time PCR (qPCR) reveal a lack of transparent and comprehensive reporting of essential technical information. Reporting standards are significantly improved in publications that cite the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines, although such publications are still vastly outnumbered by those that do not.
|
|
2. |
- Zhaunerchyk, Vitali, et al.
(författare)
-
Using covariance mapping to investigate the dynamics of multi-photon ionization processes of Ne atoms exposed to X-FEL pulses
- 2013
-
Ingår i: Journal of Physics B. - : IOP Publishing. - 0953-4075 .- 1361-6455. ; 46:16, s. 164034-
-
Tidskriftsartikel (refereegranskat)abstract
- We report on a detailed investigation into the electron emission processes of Ne atoms exposed to intense femtosecond x-ray pulses, provided by the Linac Coherent Light Source Free Electron Laser (FEL) at Stanford. The covariance mapping technique is applied to analyse the data, and the capability of this approach to disentangle both linear and nonlinear correlation features which may be hidden on coincidence maps of the same data set is demonstrated. Different correction techniques which enable improvements on the quality of the spectral features extracted from the covariance maps are explored. Finally, a method for deriving characteristics of the x-ray FEL pulses based on covariance mapping in combination with model simulations is presented.
|
|
3. |
- Angelova, G., et al.
(författare)
-
Observation of two-dimensional longitudinal-transverse correlations in an electron beam by laser-electron interactions
- 2008
-
Ingår i: Physical Review Special Topics - Accelerators and Beams. - 1098-4402. ; 11:7
-
Tidskriftsartikel (refereegranskat)abstract
- During the preparatory work for the optical-replica synthesizer experiment in the free-electron laser FLASH at DESY, we were able to superimpose a short, approximately 200 fs long pulse from a frequencydoubled mode-locked erbium laser with titanium-sapphire amplifier and an approximately 20 ps long electron bunch in an undulator. This induces an energy modulation in a longitudinal slice of the electron bunch. A magnetic chicane downstream of the undulator converts the energy modulation into a density modulation within the slice that causes the emission of coherent optical transition radiation from a silver-coated silicon screen. Varying the relative timing between electron and laser, we use a camera to record two-dimensional images of the slices as a function of the longitudinal position within the electron bunch.
|
|
4. |
- Berrah, Nora, et al.
(författare)
-
Double-core-hole spectroscopy for chemical analysis with an intense X-ray femtosecond laser
- 2011
-
Ingår i: Proceedings of the National Academy of Sciences of the United States of America. - : Proceedings of the National Academy of Sciences. - 0027-8424 .- 1091-6490. ; 108:41, s. 16912-16915
-
Tidskriftsartikel (refereegranskat)abstract
- Theory predicts that double-core-hole (DCH) spectroscopy can provide a new powerful means of differentiating between similar chemical systems with a sensitivity not hitherto possible. Although DCH ionization on a single site in molecules was recently measured with double-and single-photon absorption, double-core holes with single vacancies on two different sites, allowing unambiguous chemical analysis, have remained elusive. Here we report that direct observation of double-core holes with single vacancies on two different sites produced via sequential two-photon absorption, using short, intense X-ray pulses from the Linac Coherent Light Source free-electron laser and compare it with theoretical modeling. The observation of DCH states, which exhibit a unique signature, and agreement with theory proves the feasibility of the method. Our findings exploit the ultrashort pulse duration of the free-electron laser to eject two core electrons on a time scale comparable to that of Auger decay and demonstrate possible future X-ray control of physical inner-shell processes.
|
|
5. |
- Larsson, Mats, et al.
(författare)
-
Double core-hole formation in small molecules at the LCLS free electron laser
- 2013
-
Ingår i: Journal of Physics B. - : IOP Publishing. - 0953-4075 .- 1361-6455. ; 46:16, s. 164030-
-
Tidskriftsartikel (refereegranskat)abstract
- We have investigated nonlinear processes in small molecules by x-ray photoelectron spectroscopy using the Linac Coherent Light Source free electron laser, and by simulations. The main focus of the experiments was the formation of the two-site double core-hole (tsDCH) states in the molecules CO2, N2O and N-2. These experiments are described in detail and the results are compared with simulations of the photoelectron spectra. The double core-hole states, and in particular the tsDCH states, have been predicted to be highly sensitive to the chemical environment. The theory behind this chemical sensitivity is validated by the experiments. Furthermore, our simulations of the relative integrated intensities of the peaks associated with the nonlinear processes show that this type of simulation, in combination with experimental data, provides a useful tool for estimating the duration of ultra-short x-ray pulses.
|
|
6. |
- Marin, Ida, et al.
(författare)
-
Establishment of a clinical SPECT/CT protocol for imaging of(161)Tb
- 2020
-
Ingår i: Ejnmmi Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 7:1
-
Tidskriftsartikel (refereegranskat)abstract
- Background It has been proposed, and preclinically demonstrated, that(161)Tb is a better alternative to(177)Lu for the treatment of small prostate cancer lesions due to its high emission of low-energy electrons.Tb-161 also emits photons suitable for single-photon emission computed tomography (SPECT) imaging. This study aims to establish a SPECT protocol for(161)Tb imaging in the clinic. Materials and methods Optimal settings using various gamma-camera collimators and energy windows were explored by imaging a Jaszczak phantom, including hollow-sphere inserts, filled with(161)Tb. The collimators examined were extended low-energy general purpose (ELEGP), medium-energy general purpose (MEGP), and low-energy high resolution (LEHR), respectively. In addition, three ordered subset expectation maximization (OSEM) algorithms were investigated: attenuation-corrected OSEM (A-OSEM); attenuation and dual- or triple-energy window scatter-corrected OSEM (AS-OSEM); and attenuation, scatter, and collimator-detector response-corrected OSEM (ASC-OSEM), where the latter utilized Monte Carlo-based reconstruction. Uniformity corrections, using intrinsic and extrinsic correction maps, were also investigated. Image quality was assessed by estimated recovery coefficients (RC), noise, and signal-to-noise ratio (SNR). Sensitivity was determined using a circular flat phantom. Results The best RC and SNR were obtained at an energy window between 67.1 and 82.1 keV. Ring artifacts, caused by non-uniformity, were removed with extrinsic uniformity correction for the energy window between 67.1 and 82.1 keV, but not with intrinsic correction. Analyzing the lower energy window between 48.9 and 62.9 keV, the ring artifacts remained after uniformity corrections. The recovery was similar for the different collimators when using a specific OSEM reconstruction. Recovery and SNR were highest for ASC-OSEM, followed by AS-OSEM and A-OSEM. When using the optimized parameter setting, the resolution of(161)Tb was higher than for(177)Lu (8.4 +/- 0.7 vs. 10.4 +/- 0.6 mm, respectively). The sensitivities for(161)Tb and(177)Lu were 7.41 and 8.46 cps/MBq, respectively. Conclusion SPECT with high resolution is feasible with(161)Tb; however, extrinsic uniformity correction is recommended to avoid ring artifacts. The LEHR collimator was the best choice of the three tested to obtain a high-resolution image. Due to the complex emission spectrum of low-energy photons, window-based scatter correction had a minor impact on the image quality compared to using attenuation correction only. On the other hand, performing attenuation, scatter, and collimator-detector correction clearly improved image quality. Based on these data, SPECT-based dosimetry for(161)Tb-labeled radiopharmaceuticals is feasible.
|
|
7. |
|
|
8. |
|
|
9. |
- Salén, Peter, et al.
(författare)
-
Femtosecond photo-induced dissociation of the trihalide anions I 3 - and I2Br- in solution
- 2004
-
Ingår i: ULTRAFAST PHENOMENA XIV. - 3540241108 ; , s. 499-501
-
Konferensbidrag (refereegranskat)abstract
- The photo-induced dissociation of the trihalide anions I3 - and I2Br- in methanol and acetonitrile solution is investigated using magic angle and polarization sensitive femtosecond transient absorption spectroscopy. The dissociation of I 2Br- and I3 - in acetonitrile are found to be very similar, except at the earliest times. A noticeable solvent dependence for the dissociation process is seen, e.g. in the degree of vibrational coherence and the rotational temperature of the I2 - fragment and in the amount of recombination.
|
|
10. |
|
|