SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Andersson Sundén Erik) srt2:(2010-2014)"

Sökning: WFRF:(Andersson Sundén Erik) > (2010-2014)

  • Resultat 1-10 av 22
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andersson, Peter, 1981-, et al. (författare)
  • Design and initial 1D radiography tests of the FANTOM mobile fast-neutron radiography and tomography system
  • 2014
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 756, s. 82-93
  • Tidskriftsartikel (refereegranskat)abstract
    • The FANTOM system is a tabletop sized fast-neutron radiography and tomography system newly developed at the Applied Nuclear Physics Division of Uppsala University. The main purpose of the system is to provide time-averaged steam-and-water distribution measurement capability inside the metallic structures of two-phase test loops for Light Water Reactor thermal-hydraulic studies using a portable fusion neutron generator. The FANTOM system provides a set of 1D neutron transmission data, which may be inserted into tomographic reconstruction algorithms to achieve a 2D mapping of the steam-and-water distribution. In this paper, the selected design of FANTOM is described and motivated. The detector concept is based on plastic scintillator elements, separated for spatial resolution. Analysis of pulse heights on an event-to-event basis is used for energy discrimination. Although the concept allows for close stacking of a large number of detector elements, this demonstrator is equipped with only three elements in the detector and one additional element for monitoring the yield from the neutron generator. The first measured projections on test objects of known configurations are presented. These were collected using a Sodern Genie 16 neutron generator with an isotropic yield of about 1E8 neutrons per second, and allowed for characterization of the instrument’s capabilities. At an energy threshold of 10 MeV, the detector offered a count rate of about 500 cps per detector element. The performance in terms of spatial resolution was validated by fitting a Gaussian Line Spread Function to the experimental data, a procedure that revealed a spatial unsharpness in good agreement with the predicted FWHM of 0.5 mm.
  •  
2.
  • Andersson, Peter, 1981-, et al. (författare)
  • Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator
  • 2014
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 85:8, s. 085109-
  • Tidskriftsartikel (refereegranskat)abstract
    • In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the void distribution in these loops.Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed.In this article, three axially-symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper.Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020 and 0.022 cm-1, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful indication on the flow mode, and a visualization of the radial material distribution can be obtained. A benefit of this system is its potential to be mounted at any axial height of a two-phase test section without requirements for pre-fabricated entrances or windows. This could mean a significant increase in flexibility of the void distribution assessment capability at many existing two-phase test loops.
  •  
3.
  • Andersson Sundén, Erik, 1979- (författare)
  • Neutron Spectrometry Techniques for Fusion Plasmas : Instrumentation and Performance
  • 2010
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Neutron are emitted from a deuterium plasma with energies around 2.5 MeV. The neutron spectrum is intimately related to the ion velocity distribution of the plasma. As a consequence, the analysis of neutron energy spectra can give information of the plasma rotation, the ion temperature, heating efficiency and fusion power. The upgraded magnetic proton recoil spectrometer (MPRu), based on the thin-foil technique, is installed at the tokamak JET. The upgrade of the spectrometer was done to allow for measurements of deuterium plasmas. This thesis describes the hardware, the data reduction scheme and the kind of fusion plasma parameters that can be estimated from the data of the MPRu. The MPRu data from 3rd harmonic ion cyclotron resonance and beam heating are studied. Other neutron spectrometer techniques are reviewed as well, in particular in the aspect of suitability for neutron emission spectrometry at ITER. Each spectrometer technique is evaluated using synthetic data which is obtained from standard scenarios of ITER. From this evaluation, we conclude that the thin-foil technique is the best technique to measure, e.g., the ion temperature in terms of time resolution.
  •  
4.
  • Hellesen, Carl, 1980-, et al. (författare)
  • Neutron emission generated by fast deuterons accelerated with ion cyclotron heating at JET
  • 2010
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 0029-5515 .- 1741-4326. ; 50:2
  • Tidskriftsartikel (refereegranskat)abstract
    • For the first time, the neutron emission from JET plasmas heated with combined deuterium neutral beam injection and third harmonic ion cyclotron radio frequency heating have been studied with neutron emission spectroscopy (NES). Very high DD neutron rates were observed with only modest external heating powers, which was attributed to acceleration of deuterium beam ions to energies of about 2-3 MeV, where the DD reactivity is on a par of that of the DT reaction. Fast deuterium energy distributions were derived from analysis of NES data and confirm acceleration of deuterium beam ions up to energies around 3 MeV, in agreement with theoretical predictions. The high neutron rates allowed for observations of changes in the fast deuterium populations on a time scale of 50 ms. Correlations were seen between fast deuterium ions at different energies and magnetohydrodynamic activities, such as monster sawtooth crashes and toroidal Alfven eigenmodes.
  •  
5.
  • Andersson Sundén, Erik, et al. (författare)
  • Evaluation of neutron spectrometer techniques for ITER using synthetic data
  • 2013
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 701, s. 62-71
  • Tidskriftsartikel (refereegranskat)abstract
    • A neutron spectrometer at ITER is expected to provide estimates of plasma parameters such as ion temperature, Ti, fuel ion ratio, nt/nd, and Qthermal/Qtot, with 10-20% precision at a time resolution, Δt, of at least 100 ms. The present paper describes a method for evaluating different neutron spectroscopy techniques based on their instrumental response functions and synthetic measurement data. We include five different neutron spectrometric techniques with realistic response functions, based on simulations and measurements where available. The techniques are magnetic proton recoil, thin-foil proton recoil, gamma discriminating organic scintillator, diamond and time-of-flight. The reference position and line of sight of a high resolution neutron spectrometer on ITER are used in the study. ITER plasma conditions are simulated for realistic operating scenarios. The ITER conditions evaluated are beam and radio frequency heated and thermal deuterium-tritium plasmas. Results are given for each technique in terms of the estimated time resolution at which the parameter determination can be made within the required precision (here 10% for Ti and the relative intensities of NB and RF emission components). It is shown that under the assumptions made, the thin-foil techniques out-perform the other spectroscopy techniques in practically all measurement situations. For thermal conditions, the range of achieved Δt in the determination of Ti varies in time scales from ms (for the magnetic and thin-foil proton recoil) to s (for gamma discriminating organic scintillator).
  •  
6.
  • Andersson Sundén, Erik, et al. (författare)
  • Instrumentation for neutron emission spectrometry in use at JET
  • 2010
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 623:2, s. 681-685
  • Tidskriftsartikel (refereegranskat)abstract
    • The present contribution discusses two neutron spectrometers: the time-of-flight spectrometer (TOFOR) and the magnetic proton recoil spectrometer (MPRu). TOFOR uses fast plastic scintillators equipped with digital time-stamping electronics to register the time of each eligible scintillation event. The time trace for each detector is acquired practically dead-time free. The detectors of the MPRu are of phoswich type and each detector is connected to a digital transient recorder card that stores the full waveform for an event. By using phoswich detectors, pulse-shape discrimination techniques can be applied offline to distinguish signal events from background. A future upgrade of TOFOR could be digital “hybrid” cards, which store correlated time and waveform information. This information can be used to decrease the background level in the ttof spectrum, thereby increasing the operating range.
  •  
7.
  • Binda, Federico, et al. (författare)
  • Forward fitting of experimental data from a NE213 neutron detector installed with the magnetic proton recoil upgraded spectrometer at JET
  • 2014
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 85:11, s. 11E123-
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, we present the results obtained from the data analysis of neutron spectra measured with a NE213 liquid scintillator at JET. We calculated the neutron response matrix of the instrument combining MCNPX simulations, a generic proton light output function measured with another detector and the fit of data from ohmic pulses. For the analysis, we selected a set of pulses with neutral beam injection heating (NBI) only and we applied a forward fitting procedure of modeled spectral components to extract the fraction of thermal neutron emission. The results showed the same trend of the ones obtained with the dedicated spectrometer TOFOR, even though the values from the NE213 analysis were systematically higher. This discrepancy is probably due to the different lines of sight of the two spectrometers (tangential for the NE213, vertical for TOFOR). The uncertainties on the thermal fraction estimates were from 4 to 7 times higher than the ones from the TOFOR analysis.
  •  
8.
  • Cazzaniga, C., et al. (författare)
  • Single crystal diamond detector measurements of deuterium-deuterium and deuterium-tritium neutrons in Joint European Torus fusion plasmas
  • 2014
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 85:4, s. 043506-
  • Tidskriftsartikel (refereegranskat)abstract
    • First simultaneous measurements of deuterium-deuterium (DD) and deuterium-tritium neutrons from deuterium plasmas using a Single crystal Diamond Detector are presented in this paper. The measurements were performed at JET with a dedicated electronic chain that combined high count rate capabilities and high energy resolution. The deposited energy spectrum from DD neutrons was successfully reproduced by means of Monte Carlo calculations of the detector response function and simulations of neutron emission from the plasma, including background contributions. The reported results are of relevance for the development of compact neutron detectors with spectroscopy capabilities for installation in camera systems of present and future high power fusion experiments.
  •  
9.
  • Eriksson, Jacob, et al. (författare)
  • Finite Larmor radii effects in fast ion measurements as demonstrated using neutron emission spectrometry of JET plasmas heated with 3rd harmonic ICRF
  • 2011
  • Ingår i: 38th EPS Conference on Plasma Physics 2011 (EPS 2011): Europhysics Conference Abstracts. - 2914771681
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • This paper demonstrates how the finite Larmor radii (FLR) of fast ions can affect fast ion measurements by studying data from the neutron time-of-flight spectrometer TOFOR. Neutron spectra were calculated from a model of the fast ion velocity distribution for a JET experiment with 3rd harmonic ICRF heating of deuterium beams. It was found that  FLR effects need to be considered to get a good description of the data,  if the Larmor radius of the fast ions are comparable to the width of the field of view of the instrument. This applies not only to results from neutron spectrometry but also to other types of fast ion diagnostics.
  •  
10.
  • Eriksson, Jacob, et al. (författare)
  • Finite Larmor radii effects in fast ion measurements with neutron emission spectrometry
  • 2013
  • Ingår i: Plasma Physics and Controlled Fusion. - : IOP Publishing. - 0741-3335 .- 1361-6587. ; 55:1, s. 015008-
  • Tidskriftsartikel (refereegranskat)abstract
    • When analysing data from fast ion measurements it is normally assumed that the gyro-phase distribution of the ions is isotropic within the field of view of the measuring instrument. This assumption is not valid if the Larmor radii of the fast ions are comparable to—or larger than—the gradient scale length in the spatial distribution of the ions, and if this scale length is comparable to—or smaller than—the width of the field of view of the measuring instrument. In this paper the effect of such an anisotropy is demonstrated by analysing neutron emission spectrometry data from a JET experiment with deuterium neutral beams together with radiofrequency heating at the third harmonic of the deuterium cyclotron frequency. In the experiment, the neutron time-of-flight spectrometer TOFOR was used to measure the neutrons from the d(d,n) 3 He-reaction. Comparison of the experimental data with Monte Carlo calculations shows that the finite Larmor radii of the fast ions need to be included in the modelling to get a good description of the data. Similar effects are likely to be important for other fast ion diagnostics, such as γ -ray spectroscopy and neutral particle analysis, as well.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 22

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy