SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Becker Richard C.) ;srt2:(2006-2009)"

Sökning: WFRF:(Becker Richard C.) > (2006-2009)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Abdesselam, A., et al. (författare)
  • Engineering for the ATLAS SemiConductor Tracker (SCT) end-cap
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221 .- 1748-0221. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS SemiConductor Tracker (SCT) is a silicon-strip tracking detector which forms part of the ATLAS inner detector. The SCT is designed to track charged particles produced in proton-proton collisions at the Large Hadron Collider (LHC) at CERN at an energy of 14 TeV. The tracker is made up of a central barrel and two identical end-caps. The barrel contains 2112 silicon modules, while each end-cap contains 988 modules. The overall tracking performance depends not only on the intrinsic measurement precision of the modules but also on the characteristics of the whole assembly, in particular, the stability and the total material budget. This paper describes the engineering design and construction of the SCT end-caps, which are required to support mechanically the silicon modules, supply services to them and provide a suitable environment within the inner detector. Critical engineering choices are highlighted and innovative solutions are presented - these will be of interest to other builders of large-scale tracking detectors. The SCT end-caps will be fully connected at the start of 2008. Further commissioning will continue, to be ready for proton-proton collision data in 2008.
  •  
3.
  • Abdesselam, A., et al. (författare)
  • The ATLAS semiconductor tracker end-cap module
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 575:3, s. 353-389
  • Tidskriftsartikel (refereegranskat)abstract
    • The challenges for the tracking detector systems at the LHC are unprecedented in terms of the number of channels, the required read-out speed and the expected radiation levels. The ATLAS Semiconductor Tracker. (SCT) end-caps have a total of about 3 million electronics channels each reading out every 25 ns into its own on-chip 3.3 mu s buffer. The highest anticipated dose after 10 years operation is 1.4x10(14) cm(-2) in units of 1 MeV neutron equivalent (assuming the damage factors scale with the non-ionising energy loss). The forward tracker has 1976 double-sided modules, mostly of area similar to 70 cm(2), each having 2 x 768 strips read out by six ASICs per side. The requirement to achieve an average perpendicular radiation length of 1.5% X-0, while coping with up to 7 W dissipation per module (after irradiation), leads to stringent constraints on the thermal design. The additional requirement of 1500e(-) equivalent noise charge (ENC) rising to only 1800e(-) ENC after irradiation, provides stringent design constraints on both the high-density Cu/Polyimide flex read-out circuit and the ABCD3TA read-out ASICs. Finally, the accuracy of module assembly must not compromise the 16 mu m (r phi) resolution perpendicular to the strip directions or 580 mu m radial resolution coming from the 40 mrad front-back stereo angle. A total of 2210 modules were built to the tight tolerances and specifications required for the SCT. This was 234 more than the 1976 required and represents a yield of 93%. The component flow was at times tight, but the module production rate of 40-50 per week was maintained despite this. The distributed production was not found to be a major logistical problem and it allowed additional flexibility to take advantage of where the effort was available, including any spare capacity, for building the end-cap modules. The collaboration that produced the ATLAS SCT end-cap modules kept in close contact at all times so that the effects of shortages or stoppages at different sites could be rapidly resolved.
  •  
4.
  • Doornenbal, P., et al. (författare)
  • RISING: Gamma‐ray Spectroscopy with Radioactive Beams at GSI
  • 2007
  • Ingår i: AIP Conference Proceedings. - : AIP. - 0094-243X. - 9780735413283 ; 891, s. 99-107
  • Konferensbidrag (refereegranskat)abstract
    • The Rare Isotope Spectroscopic INvestigation at GSI (RISING) project is a major pan‐European collaboration. Its physics aims are the studies of exotic nuclear matter with abnormal proton‐to‐neutron ratios compared with naturally occurring isotopes. RISING combines the FRagment Separator (FRS) which allows relativistic energies and projectile fragmentation reactions with EUROBALL Ge Cluster detectors for γ spectroscopic research. The RISING setup can be used in two different configurations. Either the nuclei of interest are investigated after being stopped or the heavy ions hit a secondary target at relativistic energies and the thereby occurring excitations are studied. For the latter case, MINIBALL Ge detectors and the HECTOR array are used in addition. Example achievements of the Fast Beam setup are presented and compared to various shell model calculations, while for the Stopped Beam setup initial results are shown.
  •  
5.
  • Kessler, Richard, et al. (författare)
  • First-Year Sloan Digital Sky Survey-II Supernova Results : Hubble Diagram and Cosmological Parameters
  • 2009
  • Ingår i: Astrophysical Journal Supplement Series. - : American Astronomical Society. - 0067-0049 .- 1538-4365. ; 185:1, s. 32-84
  • Tidskriftsartikel (refereegranskat)abstract
    • We present measurements of the Hubble diagram for 103 Type Ia supernovae (SNe) with redshifts 0.04 < z < 0.42, discovered during the first season (Fall 2005) of the Sloan Digital Sky Survey-II (SDSS-II) Supernova Survey. These data fill in the redshift "desert" between low- and high-redshift SN Ia surveys. Within the framework of the MLCS2K2 light-curve fitting method, we use the SDSS-II SN sample to infer the mean reddening parameter for host galaxies, RV = 2.18 ± 0.14stat ± 0.48syst, and find that the intrinsic distribution of host-galaxy extinction is well fitted by an exponential function, P(AV ) = exp(-AV /τV), with τV = 0.334 ± 0.088 mag. We combine the SDSS-II measurements with new distance estimates for published SN data from the ESSENCE survey, the Supernova Legacy Survey (SNLS), the Hubble Space Telescope (HST), and a compilation of Nearby SN Ia measurements. A new feature in our analysis is the use of detailed Monte Carlo simulations of all surveys to account for selection biases, including those from spectroscopic targeting. Combining the SN Hubble diagram with measurements of baryon acoustic oscillations from the SDSS Luminous Red Galaxy sample and with cosmic microwave background temperature anisotropy measurements from the Wilkinson Microwave Anisotropy Probe, we estimate the cosmological parameters w and ΩM, assuming a spatially flat cosmological model (FwCDM) with constant dark energy equation of state parameter, w. We also consider constraints upon ΩM and ΩΛ for a cosmological constant model (ΛCDM) with w = -1 and non-zero spatial curvature. For the FwCDM model and the combined sample of 288 SNe Ia, we find w = -0.76 ± 0.07(stat) ± 0.11(syst), ΩM = 0.307 ± 0.019(stat) ± 0.023(syst) using MLCS2K2 and w = -0.96 ± 0.06(stat) ± 0.12(syst), ΩM = 0.265 ± 0.016(stat) ± 0.025(syst) using the SALT-II fitter. We trace the discrepancy between these results to a difference in the rest-frame UV model combined with a different luminosity correction from color variations; these differences mostly affect the distance estimates for the SNLS and HST SNe. We present detailed discussions of systematic errors for both light-curve methods and find that they both show data-model discrepancies in rest-frame U band. For the SALT-II approach, we also see strong evidence for redshift-dependence of the color-luminosity parameter (β). Restricting the analysis to the 136 SNe Ia in the Nearby+SDSS-II samples, we find much better agreement between the two analysis methods but with larger uncertainties: w = -0.92 ± 0.13(stat)+0.10 -0.33(syst) for MLCS2K2 and w = -0.92 ± 0.11(stat)+0.07 -0.15 (syst) for SALT-II.
  •  
6.
  • Alexander, John H., et al. (författare)
  • Apixaban, an oral, direct, selective factor Xa inhibitor, in combination with antiplatelet therapy after acute coronary syndrome : results of the Apixaban for Prevention of Acute Ischemic and Safety Events (APPRAISE) trial
  • 2009
  • Ingår i: Circulation. - 0009-7322 .- 1524-4539. ; 119:22, s. 2877-2885
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: After an acute coronary syndrome, patients remain at risk of recurrent events. Apixaban, an oral direct factor Xa inhibitor, is a novel anticoagulant that may reduce these events but also poses a risk of bleeding. METHODS AND RESULTS: Apixaban for Prevention of Acute Ischemic and Safety Events (APPRAISE) was a phase 2, double-blind, placebo-controlled, dose-ranging study. Patients (n=1715) with recent ST-elevation or non-ST-elevation acute coronary syndrome were randomized to 6 months of placebo (n=611) or 1 of 4 doses of apixaban: 2.5 mg twice daily (n=317), 10 mg once daily (n=318), 10 mg twice daily (n=248), or 20 mg once daily (n=221). Nearly all patients received aspirin; 76% received clopidogrel. The primary outcome was International Society of Thrombosis and Hemostasis major or clinically relevant nonmajor bleeding. A secondary outcome was cardiovascular death, myocardial infarction, severe recurrent ischemia, or ischemic stroke. At the recommendation of the Data Monitoring Committee, the 2 higher-dose apixaban arms were discontinued because of excess total bleeding. Compared with placebo, apixaban 2.5 mg twice daily (hazard ratio, 1.78; 95% confidence interval, 0.91 to 3.48; P=0.09) and 10 mg once daily (hazard ratio, 2.45; 95% confidence interval, 1.31 to 4.61; P=0.005) resulted in a dose-dependent increase in major or clinically relevant nonmajor bleeding. Apixaban 2.5 mg twice daily (hazard ratio, 0.73; 95% confidence interval, 0.44 to 1.19; P=0.21) and 10 mg once daily (hazard ratio, 0.61; 95% confidence interval, 0.35 to 1.04; P=0.07) resulted in lower rates of ischemic events compared with placebo. The increase in bleeding was more pronounced and the reduction in ischemic events was less evident in patients taking aspirin plus clopidogrel than in those taking aspirin alone. CONCLUSIONS: We observed a dose-related increase in bleeding and a trend toward a reduction in ischemic events with the addition of apixaban to antiplatelet therapy in patients with recent acute coronary syndrome. The safety and efficacy of apixaban may vary depending on background antiplatelet therapy. Further testing of apixaban in patients at risk of recurrent ischemic events is warranted.
  •  
7.
  • Pischon, Tobias, et al. (författare)
  • Body size and risk of colon and rectal cancer in the European prospective investigation into cancer and nutrition (EPIC)
  • 2006
  • Ingår i: Journal of the National Cancer Institute. - : Oxford University Press (OUP). - 1460-2105 .- 0027-8874. ; 98:13, s. 920-931
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Body weight and body mass index (BMI) are positively related to risk of colon cancer in men, whereas weak or no associations exist in women. This discrepancy may be related to differences in fat distribution between sexes or to the use of hormone replacement therapy (HRT) in women. Methods: We used multivariable adjusted Cox proportional hazards models to examine the association between anthropometric measures and risks of colon and rectal cancer among 368 277 men and women who were free of cancer at baseline from nine countries of the European Prospective Investigation Into Cancer and Nutrition. All statistical tests were two-sided. Results: During 6.1 years of follow-up, we identified 984 and 586 patients with colon and rectal cancer, respectively. Body weight and BMI were statistically significantly associated with colon cancer risk in men (highest versus lowest quintile of BMI, relative risk [RR] = 1.55, 95% confidence interval [CI] = 1.12 to 2.15; P-trend =.006) but not in women. In contrast, comparisons of the highest to the lowest quintile showed that several anthropometric measures, including waist circumference (men, RR = 1.39,95% CI = 1.01 to 1.93; P-trend = .001; women, RR = 1.48, 95% CI = 1.08 to 2.03; P-trend =.008), waist-to-hip ratio (WHR; men, RR = 1.51, 95% CI = 1.06 to 2.15; P-trend =.006; women, RR = 1.52, 95% CI = 1.12 to 2.05; P-trend =.002), and height (men, RR = 1.40, 95% CI = 0.99 to 1.98; P-trend =.04; women, RR = 1.79, 95% CI = 1.30 to 2.46; P-trend <.001) were related to colon cancer risk in both sexes. The estimated absolute risk of developing colon cancer within 5 years was 203 and 131 cases per 100 000 men and 129 and 86 cases per 100000 women in the highest and lowest quintiles of WHR, respectively. Upon further stratification, no association of waist circumference and WHR with risk of colon cancer was observed among postmenopausal women who used HRT. None of the anthropometric measures was statistically significantly related to rectal cancer. Conclusions: Waist circumference and WHR, indicators of abdominal obesity, were strongly associated with colon cancer risk in men and women in this population. The association of abdominal obesity with colon cancer risk may vary depending on HRT use in postmenopausal women; however, these findings require confirmation in future studies.
  •  
8.
  • Wallentin, Lars, 1943-, et al. (författare)
  • Ticagrelor versus clopidogrel in patients with acute coronary syndromes
  • 2009
  • Ingår i: New England Journal of Medicine. - 0028-4793 .- 1533-4406. ; 361:11, s. 1045-1057
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Ticagrelor is an oral, reversible, direct-acting inhibitor of the adenosine diphosphate receptor P2Y12 that has a more rapid onset and more pronounced platelet inhibition than clopidogrel. METHODS: In this multicenter, double-blind, randomized trial, we compared ticagrelor (180-mg loading dose, 90 mg twice daily thereafter) and clopidogrel (300-to-600-mg loading dose, 75 mg daily thereafter) for the prevention of cardiovascular events in 18,624 patients admitted to the hospital with an acute coronary syndrome, with or without ST-segment elevation. RESULTS: At 12 months, the primary end point--a composite of death from vascular causes, myocardial infarction, or stroke--had occurred in 9.8% of patients receiving ticagrelor as compared with 11.7% of those receiving clopidogrel (hazard ratio, 0.84; 95% confidence interval [CI], 0.77 to 0.92; P<0.001). Predefined hierarchical testing of secondary end points showed significant differences in the rates of other composite end points, as well as myocardial infarction alone (5.8% in the ticagrelor group vs. 6.9% in the clopidogrel group, P=0.005) and death from vascular causes (4.0% vs. 5.1%, P=0.001) but not stroke alone (1.5% vs. 1.3%, P=0.22). The rate of death from any cause was also reduced with ticagrelor (4.5%, vs. 5.9% with clopidogrel; P<0.001). No significant difference in the rates of major bleeding was found between the ticagrelor and clopidogrel groups (11.6% and 11.2%, respectively; P=0.43), but ticagrelor was associated with a higher rate of major bleeding not related to coronary-artery bypass grafting (4.5% vs. 3.8%, P=0.03), including more instances of fatal intracranial bleeding and fewer of fatal bleeding of other types. CONCLUSIONS: In patients who have an acute coronary syndrome with or without ST-segment elevation, treatment with ticagrelor as compared with clopidogrel significantly reduced the rate of death from vascular causes, myocardial infarction, or stroke without an increase in the rate of overall major bleeding but with an increase in the rate of non-procedure-related bleeding.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy