SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Hauschild M.) srt2:(2005-2009)"

Search: WFRF:(Hauschild M.) > (2005-2009)

  • Result 1-7 of 7
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Schael, S, et al. (author)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Research review (peer-reviewed)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Abate, E., et al. (author)
  • Combined performance tests before installation of the ATLAS Semiconductor and Transition Radiation Tracking Detectors
  • 2008
  • In: Journal of Instrumentation. - 1748-0221. ; 3
  • Journal article (peer-reviewed)abstract
    • The ATLAS (A Toroidal LHC ApparatuS) Inner Detector provides charged particle tracking in the centre of the ATLAS experiment at the Large Hadron Collider (LHC). The Inner Detector consists of three subdetectors: the Pixel Detector, the Semiconductor Tracker (SCT), and the Transition Radiation Tracker (TRT). This paper summarizes the tests that were carried out at the final stage of SCT+TRT integration prior to their installation in ATLAS. The combined operation and performance of the SCT and TRT barrel and endcap detectors was investigated through a series of noise tests, and by recording the tracks of cosmic rays. This was a crucial test of hardware and software of the combined tracker detector systems. The results of noise and cross-talk tests on the SCT and TRT in their final assembled configuration, using final readout and supply hardware and software, are reported. The reconstruction and analysis of the recorded cosmic tracks allowed testing of the offline analysis chain and verification of basic tracker performance parameters, such as efficiency and spatial resolution, in combined operation before installation.
  •  
3.
  • Ketelhut, S., et al. (author)
  • gamma-Ray Spectroscopy at the Limits : First Observation of Rotational Bands in Lr-255
  • 2009
  • In: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 102:21, s. 212501-
  • Journal article (peer-reviewed)abstract
    • The rotational band structure of Lr-255 has been investigated using advanced in-beam gamma-ray spectroscopic techniques. To date, Lr-255 is the heaviest nucleus to be studied in this manner. One rotational band has been unambiguously observed and strong evidence for a second rotational structure was found. The structures are tentatively assigned to be based on the 1/2(-)[521] and 7/2(-)[514] Nilsson states, consistent with assignments from recently obtained alpha decay data. The experimental rotational band dynamic moment of inertia is used to test self-consistent mean-field calculations using the Skyrme SLy4 interaction and a density-dependent pairing force.
  •  
4.
  • Mason, P, et al. (author)
  • Octupole signatures in Ba-124,Ba-125
  • 2005
  • In: Journal of Physics G. - : IOP Publishing. - 0954-3899 .- 1361-6471. ; 31:10, s. S1729-S1733
  • Journal article (peer-reviewed)abstract
    • The gamma decay of the nuclei Ba-121,Ba-125 has been investigated with the EUROBALL array, using the reaction Ni-64+Ni-64 at E-beam = 255 and 261 MeV. Six new E1 transitions have been found in the nucleus Ba-125, suggesting a significant role of octupole correlations in the origin of its parity doublets. The J(pi) = 3(-) level of the nucleus Ba-124 has been identified for the first time. Its excitation energy is in very good agreement with a prediction based on a microscopic model including octupole interactions.
  •  
5.
  • Recchia, F, et al. (author)
  • Position resolution of the prototype AGATA triple-cluster detector from an in-beam experiment
  • 2009
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 604:3, s. 555-562
  • Journal article (peer-reviewed)abstract
    • AGATA belongs to a new generation of gamma-ray detector arrays for nuclear spectroscopy at present in its final stage of development. The detectors of these new arrays will be based on 36-fold electronically segmented coaxial germanium diodes operated in position sensitive mode. An in-beam test of the AGATA prototype triple cluster detector was carried out with the purpose of demonstrating the feasibility of such detectors and in order to measure the most sensitive parameters for their overall performance. An inverse kinematics reaction was performed, using a Ti-48 beam at an energy of 100MeV, impinging on a deuterated titanium tat-get. The results from the analysis of the experimental data, compared with the predictions of Monte Carlo Simulations, give an estimation of the position sensitivity of these detectors of about 5 mm FWHM, consistent with the specifications required. (C) 2009 Elsevier B.V. All rights reserved.
  •  
6.
  • Jeswiet, J., et al. (author)
  • Course content for Life Cycle Engineering and EcoDesign
  • 2007
  • In: International journal of engineering education. - 0949-149X. ; 23:6, s. 1081-1089
  • Journal article (peer-reviewed)abstract
    • There is a need to create an awareness of Life, Cycle Engineering and EcoDesign in Engineering students. Topics covered in an LCE/EcoDesign course will create an awareness of environmental impacts, especially in other design course projects. This paper suggests that an awareness of product impact upon the environment must be created at (in early stage in undergraduate education. Deciding what to include in an LCE/EcoDesign Course can e difficult because there are many different views on the subject. However, there are more similarities than differences. All LCE/EcoDesign Engineering courses have the ultimate objective of decreasing the environmental impact of a design. It has been observed that 70% of product costs are decided tit the design stage. This can be extended to environmental impact, where it can be observed that, the design is correct, at the beginning, the environmental impact can be reduced by an estimated 70%. An LCE course does not need a high mathematical content and can give undergraduate students exposure to information that can be used in product design courses as they progress through university. The general content of such a course is suggested in this paper.
  •  
7.
  • Norkus, A, et al. (author)
  • Use of a hydrocapillary dressing in the management of highly exuding ulcers; a comparative study
  • 2005
  • In: Journal of Wound Care. - 0969-0700. ; 14:9, s. 129-432
  • Journal article (peer-reviewed)abstract
    • Objective: To evaluate the safety and performance of Alione Hydrocapillary dressing (Coloplast A/S) in the management of highly exuding chronic venous leg ulcers and compare it with two hydropolymer dressings, Tielle and Tielle Plus (Johnson & Johnson). Method: A comparative clinical trial was conducted on 97 patients with an ankle brachial pressure index ?0.8 and a highly exuding leg ulcer. Ulcer duration was at least four weeks. Treatment continued until healing or for a maximum of 12 months. Results: There was no statistically significant difference in healing time or wound area reduction between the two treatment protocols. The test dressing (Alione Hydrocapillary) had better absorption capacity and was more comfortable for the patients than the comparator dressings (Tielle/Tielle Plus) and adhered less to the wound bed. Also, more patients preferred the test dressing to their previous treatment. Although severe leakage and maceration were observed more frequently in the comparator group compared with the test group, this was not statistically significant. Conclusion: Both treatment protocols were safe and effective in treating highly exuding chronic venous leg ulcers. The test dressing performed as well as or better than the comparator dressings for all study parameters and more patients preferred the test dressing to their previous dressing compared with the comparator dressings.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-7 of 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view