SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Stone Gregg W.) srt2:(2011-2014)"

Search: WFRF:(Stone Gregg W.) > (2011-2014)

  • Result 1-4 of 4
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • D'Ascenzo, Fabrizio, et al. (author)
  • Incidence and predictors of coronary stent thrombosis : Evidence from an international collaborative meta-analysis including 30 studies, 221,066 patients, and 4276 thromboses
  • 2013
  • In: International Journal of Cardiology. - : Elsevier BV. - 0167-5273 .- 1874-1754. ; 167:2, s. 575-584
  • Journal article (peer-reviewed)abstract
    • BACKGROUND:Stent thrombosis remains among the most feared complications of percutaneous coronary intervention (PCI) with stenting. However, data on its incidence and predictors are sparse and conflicting. We thus aimed to perform a collaborative systematic review on incidence and predictors of stent thrombosis.METHODS: PubMed was systematically searched for eligible studies from the drug-eluting stent (DES) era (1/2002-12/2010). Studies were selected if including ≥2000 patients undergoing stenting or reporting on ≥25 thromboses. Study features, patient characteristics, and incidence of stent thrombosis were abstracted and pooled, when appropriate, with random-effect methods (point estimate [95% confidence intervals]), and consistency of predictors was formally appraised.RESULTS:A total of 30 studies were identified (221,066 patients, 4276 thromboses), with DES used in 87%. After a median of 22months, definite, probable, or possible stent thrombosis had occurred in 2.4% (2.0%; 2.9%), with acute in 0.4% (0.2%; 0.6%), subacute in 1.1% (1.0%; 1.3%), late in 0.5% (0.4%; 0.6%), and very late in 0.6% (0.4%; 0.8%). Similar figures were computed for studies reporting only on DES. From a total of 47 candidate variables, definite/probable stent thrombosis was more commonly and consistently predicted by early antiplatelet therapy discontinuation, extent of coronary disease, and stent number/length, with acute coronary syndrome at admission, diabetes, smoking status, and bifurcation/ostial disease also proving frequent predictors, but less consistently.CONCLUSIONS:Despite numerous possible risk factors, the most common and consistent predictors of stent thrombosis are early antiplatelet therapy discontinuation, extent of coronary disease, and stent number/length.
  •  
2.
  • Harnek, Jan, et al. (author)
  • Transcatheter Implantation of the MONARC Coronary Sinus Device for Mitral Regurgitation 1-Year Results From the EVOLUTION Phase I Study (Clinical Evaluation of the Edwards Lifesciences Percutaneous Mitral Annuloplasty System for The Treatment of Mitral Regurgitation)
  • 2011
  • In: JACC. Cardiovascular interventions. - : Elsevier BV. - 1936-8798 .- 1876-7605. ; 4:1, s. 115-122
  • Journal article (peer-reviewed)abstract
    • Objectives This study sought to assess the safety and efficacy of transcatheter valve annuloplasty in patients with mitral regurgitation (MR). Background Mitral regurgitation is associated with a worsened prognosis in patients with dilated cardiomyopathy. Surgical mitral annuloplasty reduces the septal-lateral dimension of the mitral annulus resulting in improved leaflet coaptation with a reduction in regurgitation. Percutaneous annuloplasty with the MONARC device (Edwards Lifesciences, Irvine, California) implanted within the coronary sinus is designed to reduce mitral regurgitation through a similar mechanism. Methods A total of >= 2 patients with MR grade were enrolled at 8 participating centers in 4 countries. Clinical evaluation and transthoracic echocardiography were performed at baseline and at 3, 6, and 12 months. Multislice cardiac computed tomography and coronary angiography were performed at baseline and 3 months. Results The MONARC device was implanted in 59 of 72 patients (82%). The primary safety end point (freedom from death, tamponade, or myocardial infarction at 30 days) was met in 91% of patients at 30 days and in 82% at 1 year. Computed tomography imaging documented passage of the great cardiac vein over an obtuse marginal artery in 55% of patients and was associated with angiographic coronary artery compression in 15 patients and myocardial infarction in 2 patients (3.4%). At 12 months, a reduction in MR by >= 1 grade was observed in 50.0% of 22 implanted patients with matched echocardiograms and in 85.7% of 7 patients with baseline MR >= 3 grade Conclusions Implantation of the MONARC device in the coronary sinus is feasible and may reduce MR. However, coronary artery compression may occur in patients in whom the great cardiac vein passes over a coronary artery, necessitating strategies in future studies to avoid this occurrence.
  •  