SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tumani Hayrettin) srt2:(2010-2014)"

Sökning: WFRF:(Tumani Hayrettin) > (2010-2014)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Mattsson, Niklas, 1979, et al. (författare)
  • The Alzheimer's Association external quality control program for cerebrospinal fluid biomarkers.
  • 2011
  • Ingår i: Alzheimer's & dementia : the journal of the Alzheimer's Association. - : Wiley. - 1552-5279. ; 7:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The cerebrospinal fluid (CSF) biomarkers amyloid β (Aβ)-42, total-tau (T-tau), and phosphorylated-tau (P-tau) demonstrate good diagnostic accuracy for Alzheimer's disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer's Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch-to-batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program.
  •  
2.
  • Nagy, Karin, et al. (författare)
  • Cerebrospinal fluid analyses for the diagnosis of subarachnoid haemorrhage and experience from a Swedish study. What method is preferable when diagnosing a subarachnoid haemorrhage?
  • 2013
  • Ingår i: Clinical chemistry and laboratory medicine : CCLM / FESCC. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 51:11, s. 2073-2086
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract Subarachnoid haemorrhage (SAH) has a high mortality and morbidity rate. Early SAH diagnosis allows the early treatment of a ruptured cerebral aneurysm, which improves the prognosis. Diagnostic cerebrospinal fluid (CSF) analyses may be performed after a negative computed tomography scan, but the precise analytical methods to be used have been debated. Here, we summarize the scientific evidence for different CSF methods for SAH diagnosis and describe their implementation in different countries. The principle literature search was conducted using PubMed and Scopus with the search items "cerebrospinal fluid", "subarachnoid haemorrhage", and "diagnosis". CSF analyses for SAH include visual examination, red blood cell counts, spectrophotometry for oxyhaemoglobin or bilirubin determination, CSF cytology, and ferritin measurement. The methods vary in availability and performance. There is a consensus that spectrophotometry has the highest diagnostic performance, but both oxyhaemoglobin and bilirubin determinations are susceptible to important confounding factors. Visual inspection of CSF for xanthochromia is still frequently used for diagnosis of SAH, but it is advised against because spectrophotometry has a superior diagnostic accuracy. A positive finding of CSF bilirubin is a strong indicator of an intracranial bleeding, whereas a positive finding of CSF oxyhaemoglobin may indicate an intracranial bleeding or a traumatic tap. Where spectrophotometry is not available, the combination of CSF cytology for erythrophages or siderophages and ferritin is a promising alternative.
  •  
3.
  • Otto, Markus, et al. (författare)
  • Roadmap and standard operating procedures for biobanking and discovery of neurochemical markers in ALS
  • 2012
  • Ingår i: Amyotrophic Lateral Sclerosis and other Motor Neuron Disorders. - : Informa UK Limited. - 1466-0822 .- 1743-4483. ; 13:1, s. 1-10
  • Forskningsöversikt (refereegranskat)abstract
    • Despite major advances in deciphering the neuropathological hallmarks of amyotrophic lateral sclerosis (ALS), validated neurochemical biomarkers for monitoring disease activity, earlier diagnosis, defining prognosis and unlocking key pathophysiological pathways are lacking. Although several candidate biomarkers exist, translation into clinical application is hindered by small sample numbers, especially longitudinal, for independent verification. This review considers the potential routes to the discovery of neurochemical markers in ALS, and provides a consensus statement on standard operating procedures that will facilitate multicenter collaboration, validation and ultimately clinical translation.
  •  
4.
  • Petzold, Axel, et al. (författare)
  • Neurofilament ELISA validation
  • 2010
  • Ingår i: JOURNAL OF IMMUNOLOGICAL METHODS. - 0022-1759. ; 352:1-2, s. 23-31
  • Tidskriftsartikel (refereegranskat)
  •  
5.
  • Petzold, Axel, et al. (författare)
  • Neurofilament ELISA validation
  • 2010
  • Ingår i: JIM - Journal of Immunological Methods. - : Elsevier BV. - 0022-1759 .- 1872-7905. ; 352:1-2, s. 23-31
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Neurofilament proteins (Nf) are highly specific biomarkers for neuronal death and axonal degeneration. As these markers become more widely used, an inter-laboratory validation study is required to identify assay criteria for high quality performance. METHODS: The UmanDiagnostics NF-light (R)enzyme-linked immunoabsorbent assays (ELISA) for the neurofilament light chain (NfL, 68kDa) was used to test the intra-assay and inter-laboratory coefficient of variation (CV) between 35 laboratories worldwide on 15 cerebrospinal fluid (CSF) samples. Critical factors, such as sample transport and storage, analytical delays, reaction temperature and time, the laboratories' accuracy and preparation of standards were documented and used for the statistical analyses. RESULTS: The intra-laboratory CV averaged 3.3% and the inter-laboratory CV 59%. The results from the test laboratories correlated with those from the reference laboratory (R=0.60, p<0.0001). Correcting for critical factors improved the strength of the correlation. Differences in the accuracy of standard preparation were identified as the most critical factor. Correcting for the error introduced by variation in the protein standards improved the correlation to R=0.98, p<0.0001 with an averaged inter-laboratory CV of 14%. The corrected overall inter-rater agreement was subtantial (0.6) according to Fleiss' multi-rater kappa and Gwet's AC1 statistics. CONCLUSION: This multi-center validation study identified the lack of preparation of accurate and consistent protein standards as the main reason for a poor inter-laboratory CV. This issue is also relevant to other protein biomarkers based on this type of assay and will need to be solved in order to achieve an acceptable level of analytical accuracy. The raw data of this study is available online.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy