SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Vogt Aurelie)
 

Search: WFRF:(Vogt Aurelie) > (2020) > Laboratory water-wi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Laboratory water-window x-ray microscopy

Kördel, Mikael (author)
KTH,Biomedicinsk fysik och röntgenfysik
Dehlinger, Aurelie (author)
Tech Univ Berlin, Inst Opt & Atom Phys, Hardenbergstr 36, D-10623 Berlin, Germany.;Berlin Lab Innovat Xray Technol BLiX, Hardenbergstr 36, D-10623 Berlin, Germany.
Seim, Christian (author)
Tech Univ Berlin, Inst Opt & Atom Phys, Hardenbergstr 36, D-10623 Berlin, Germany.;Berlin Lab Innovat Xray Technol BLiX, Hardenbergstr 36, D-10623 Berlin, Germany.
show more...
Vogt, Ulrich (author)
KTH,Biomedicinsk fysik och röntgenfysik
Fogelqvist, Emelie (author)
KTH,Biomedicinsk fysik och röntgenfysik
Sellberg, Jonas A. (author)
KTH,Biomedicinsk fysik och röntgenfysik
Stiel, Holger (author)
Berlin Lab Innovat Xray Technol BLiX, Hardenbergstr 36, D-10623 Berlin, Germany.;Max Born Inst MBI, Max Born Str 2A, D-12489 Berlin, Germany.
Hertz, Hans M. (author)
KTH,Biomedicinsk fysik och röntgenfysik
show less...
 (creator_code:org_t)
The Optical Society, 2020
2020
English.
In: Optica. - : The Optical Society. - 2334-2536. ; 7:6, s. 658-674
  • Research review (peer-reviewed)
Abstract Subject headings
Close  
  • Soft x-ray microscopy in the water window (similar to 285-535 eV) is an emerging and unique tool for 2D and 3D imaging of unstained intact cellular samples in their near-native state with few-10-nm detail. However, present microscopes rely on the high x-ray brightness of synchrotron-radiation sources. Having access to water-window microscopy in the home laboratory would increase the impact and extend the applicability of the method. In the present paper, we review three decades of efforts to build laboratory water-window microscopes and conclude that the method is now reaching the maturity to allow biological studies. The instruments as well as their key components are quantitatively and qualitatively compared. We find that the brightness and the reliability of the laboratory source are the most critical parameters, but that the optics as well as the sample preparation also must be optimized to enable high-resolution imaging with adequate exposure times. We then describe the two sister microscopes in Stockholm and Berlin, which allow reliable high-resolution biological imaging with short exposure times of a few tens of seconds in 2D and a few tens of minutes in 3D. They both rely on a liquid-jet laser-plasma source combined with high-reflectivity normal-incidence multilayer condenser optics, high-resolution zone-plate imaging optics, CCD detection, and cryogenic sample handling. Finally, we present several examples of biological imaging demonstrating the unique properties of these instruments. 

Subject headings

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Publication and Content Type

ref (subject category)
for (subject category)

Find in a library

  • Optica (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view