1. |
|
|
2. |
|
|
3. |
- Resch, Timothy, et al.
(författare)
-
Changes in aneurysm morphology and stent-graft configuration after endovascular repair of aneurysms of the descending thoracic aorta
- 2001
-
Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 122:1, s. 47-52
-
Tidskriftsartikel (refereegranskat)abstract
- OBJECTIVE: We sought to study changes in morphology and stent-graft configuration of descending thoracic aortic aneurysms after endovascular repair. METHODS: Twenty-three patients treated with custom-made stent-grafts were studied. The stent-graft consisted of continuous, stainless-steel Z stents mounted within a polyester graft. In the last 11 cases the stents were interconnected with 3 longitudinal wires. Contrast-enhanced spiral computed tomography was performed preoperatively and at 1, 3, and every 6 months postoperatively. Angiography was used preoperatively and at 1-year follow-up. Proximal and distal necks were assessed for diameter and length. Aneurysm diameter, endoleaks, stent-graft migration, and changes in stent-graft configuration were evaluated. RESULTS: During follow-up (median, 18 months; range, 1-48 months), excluded aneurysms decreased in diameter by 4 mm (0.5-10 mm, P =.0018). Endoleaks prevented size decrease. Five patients displayed neck dilatation, 4 at both the proximal and distal fixation sites and 1 only distally. In 7 (30%) patients there was proximal migration of the distal end of the stent-graft. Three (13%) patients displayed both distal migration of the proximal end of the stent-graft and proximal migration of the distal end of the stent-graft. There was a significant correlation between stent-graft kinking and appearance of proximal or distal stent-graft migration (P =.05 and P =.0007, respectively). In no case did the migration lead to appearance of an endoleak before intervention was performed. CONCLUSION: Excluded descending thoracic aortic aneurysms decrease in size on midterm follow-up. A subgroup of patients prone to neck dilatation might exist. A combination of neck dilatation and vector forces acting on stent-grafts in the tortuous thoracic aorta might lead to stent-graft migration.
|
|
4. |
|
|
5. |
- Sörelius, Karl, et al.
(författare)
-
Endovascular treatment of mycotic aortic aneurysms: a European multicenter study.
- 2014
-
Ingår i: Circulation. - : Lippincott Williams & Wilkins. - 1524-4539 .- 0009-7322. ; 130:24, s. 2136-42
-
Tidskriftsartikel (refereegranskat)abstract
- Mycotic aortic aneurysm (MAA) is a rare and life-threatening disease. The aim of this European multicenter collaboration was to study the durability of endovascular aortic repair (EVAR) of MAA, by assessing late infection-related complications and long-term survival.
|
|
6. |
- Alhadad, Alaa, et al.
(författare)
-
Percutaneous transluminal renal angioplasty (PTRA) and surgical revascularisation in renovascular disease - A retrospective comparison of results, complications, and mortality
- 2004
-
Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 27:2, s. 151-156
-
Tidskriftsartikel (refereegranskat)abstract
- Objective. To evaluate results, complications and mortality following percutaneous transluminal renal angioplasty (PTRA) and open surgical revascularisation for renovascular disease. Methods. A retrospective evaluation of 381 renovascular patients (median age 64, range 9-99 years, 152 women) treated at Malmo University Hospital during 1987-1996. Two hundred and sixty-two (69%) of the patients were treated with PTRA, 106 (28%) with open revascularisation. Results. Thirty-day mortality was 2% in the PTRA group and 9% after open surgery (p < 0.001). There were no differences between groups concerning the number of re-do procedures, but first re-do was performed after seven (IQR 3-14) months in the PTRA group, and after 15 (IQR 10-44) months after open revascularisation (p < 0.0001). After a median follow-up of 4 months (IQR 0-13) systolic and diastolic blood pressure (BP) had decreased (p < 0.0001) in both groups. The number of antihypertensive drugs was reduced (p < 0.0001) and S-creatinine levels were unchanged in both groups. Longtime survival assessed with log-rank analysis was better (p < 0.01) in the PTRA group. The risk ratio for death with open revascularisation was 1.69 (p < 0.01). Conclusions. In this retrospective comparison, PTRA was as effective as open revascularisation, with lower complication rate and lower early and long-time mortality, but with shorter time to first re-do.
|
|
7. |
- Björses, Katarina, et al.
(författare)
-
Kissingstents in the Aortic Bifurcation - a Valid Reconstruction for Aorto-iliac Occlusive Disease.
- 2008
-
Ingår i: European journal of vascular and endovascular surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; Aug 7, s. 424-431
-
Tidskriftsartikel (refereegranskat)abstract
- OBJECTIVE: To evaluate outcome and patency predicting factors of kissingstent treatment for aorto iliac occlusive disease (AIOD). METHODS: Patients treated with kissingstents for AOID between 1995 and 2004 at a tertiary referral center were identified through local databases. Chart review and preoperative images were used for TASC and Fontaine classification. Follow-up consisted of clinical exams, ABI and/or duplex. Patency rates were estimated by Kaplan-Meier analysis, and Cox multivariate regression was used to determine factors associated with patency. RESULTS: 173 consecutive patients (46% male, mean 64 years) were identified. TASC distribution was: A 15%, B 34%, C 10%, D 41%. Mean follow-up was 36 months (range: 1-144). 30-day mortality was 1% (2 patients), and 1-year survival was 91% (157 patients). 2 patients underwent late, open conversion and 13 patients suffered minor puncture site complications. Primary, assisted primary and secondary patency was: 97%, 99% and 100%, and 83%, 90% and 95% at twelve and 36 months respectively. There was no significant difference in patency between the TASC groups. Patency was significantly worse for patients in Fontaine class III. CONCLUSIONS: Aortoiliac kissing stents is a valid alternative to open repair for TASC A-D lesions. The procedure has low mortality and morbidity and good patency at 3 years.
|
|
8. |
|
|
9. |
- Chuter, Timothy A M, et al.
(författare)
-
A telescopic stent-graft for aortoiliac implantation
- 1997
-
Ingår i: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 13:1, s. 79-84
-
Tidskriftsartikel (refereegranskat)abstract
- OBJECTIVES: To test a new delivery system for a telescopic stent-graft. MATERIALS: Variable overlap between the components of this stent-graft combination allows length adjustment. This device differs from other multi-component stent-grafts in that both components are contained within a single delivery system. METHODS: The stent-graft was implanted in the distal thoracic to suprarenal aorta of five pigs (35-50 kg), where the arterial diameter falls by almost 50%. The proximal and distal components of the stent-graft were targeted to bony landmarks in the vertebral column. RESULTS: Inspection of completion angiograms showed both proximal and distal stent-grafts to be within 1 mm of their target locations in all five experiments. Overall combined stent-graft length varied from 13.5 cm to 16.1 cm depending on the location of the bony landmark chosen as the distal target, and on the size of the pig. CONCLUSIONS: This system may be useful for the repair of abdominal aortic aneurysm whenever preoperative sizing is difficult due to aortic tortuosity, or precluded due to the urgency of the procedure.
|
|
10. |
- Chuter, Timothy A M, et al.
(författare)
-
Aneurysm pressure following endovascular exclusion
- 1997
-
Ingår i: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 13:1, s. 85-87
-
Tidskriftsartikel (refereegranskat)abstract
- OBJECTIVES: To assess the effect of stent-graft implantation on the pressure within an abdominal aortic aneurysm. METHODS: Aneurysm exclusion was performed using an aorto-uniiliac stent-graft in eight patients. Following stent-graft implantation, pressure measurements were performed through a catheter adjacent to the graft in the aneurysm. This "aneurysm pressure" was compared with radial arterial pressure. RESULTS: The pressure was lower in the aneurysm than in the radial artery, in all cases. Mean aneurysm pressure was 36.5/33.8 mmHg, while mean radial arterial pressure was 118.5/50.5 mmHg (p < 0.05, for both systolic and diastolic pressures). These findings corresponded with a reduction in the palpable abdominal pulse, and an absence of perigraft perfusion on follow-up computerised tomography. CONCLUSION: Stent-graft implantation produces a fall in the pressure within an abdominal aortic aneurysm.
|
|