SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:su-124733"
 

Sökning: id:"swepub:oai:DiVA.org:su-124733" > Application of grap...

Application of graphitic sorbent for online microextraction of drugs in human plasma samples

Iadaresta, Francesco (författare)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
Crescenzi, Carlo (författare)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi,Universita di Salerno, Italy
Amini, Ahmad (författare)
visa fler...
Colmsjö, Anders (författare)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
Koyi, Hirsh (författare)
Karolinska Institutet,Uppsala universitet,Centrum för klinisk forskning, Gävleborg
Abdel-Rehim, Mohamed (författare)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska.
Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673 .- 1873-3778. ; 1422, s. 34-42
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In the present work a new sorbent based on graphitized carbon (CarbonX (R) COA) was evaluated in microextraction by packed sorbent (MEPS) for extraction of lidocaine and ropivacaine from human plasma samples. The new graphitic sorbent showed high recoveries of lidocaine and ropivacaine compared to C18 sorbent In the present study the G-MEPS (syringe packed with graphitic sorbent) was connect online with liquid chromatography tandem mass spectrometry (LC-MS/MS). In order to obtain a fast and reliable method different factors affecting MEPS performance were investigated. The extraction efficiency of the graphitic sorbent was compared with silica-based sorbents used in MEPS. The G-MEPS was also evaluated for reuse (50-100 times). The recoveries of lidocaine and ropivacaine from plasma samples were 79% and 82%; respectively. The method was validated according to FDA (Food and Drug Administration) guideline for bioanalytical method validation. Linearity was assessed in the range 5-2000 nmol/L, with coefficient of determination r(2) > 0,995 (n=3) for lidocaine and r(2) > 0.997 (n=3) for ropivacaine. The lower limit of quantification (LLOQ) was 5 nmol/L and the limit of detection (LOD) was 1 nmol/L for studied analytes in plasma samples. For both analytes considered in this study the accuracy values in plasma samples were ranged from 86% to 113%. The Inter-day precisions, expressed as relative standard deviation (%RSD), at three different concentrations (QC-samples) ranged from 8% to 9% for lidocaine, and from 4% to 11% for ropivacaine.

Ämnesord

NATURVETENSKAP  -- Biologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences (hsv//eng)
NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Medical Biotechnology (hsv//eng)

Nyckelord

Graphitic sorbent
Microextraction by packed sorbent
Lidocaine
Ropivacaine
Carbon X COA
Plasma samples

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy