SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-13355"
 

Sökning: id:"swepub:oai:DiVA.org:umu-13355" > Adaptive spatio-tem...

Adaptive spatio-temporal filtering of multichannel surface EMG signals

Östlund, Nils (författare)
Linköpings universitet,Umeå universitet,Radiofysik,Hälsouniversitetet,Rehabiliteringsmedicin
Yu, Jun, 1962- (författare)
SLU, Centre of Biostochastics,Centre for Biomedical Engineering and Physics, Umeå University, Umeå, Sweden, Centre of Biostochastics, Swedish University of Agricultural Sciences, Umeå, Sweden
Karlsson, Stefan (författare)
Umeå universitet,Radiofysik,Department of Biomedical Engineering and Informatics, University Hospital, 901 85 Umeå, Sweden, Centre for Biomedical Engineering and Physics, Umeå University, Umeå, Sweden
 (creator_code:org_t)
2006-03-07
2006
Engelska.
Ingår i: Medical and Biological Engineering and Computing. - : Springer Science and Business Media LLC. - 0140-0118 .- 1741-0444. ; 44:3, s. 209-215
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A motor unit (MU) is defined as an anterior horn cell, its axon, and the muscle fibres innervated by the motor neuron. A surface electromyogram (EMG) is a superposition of many different MU action potentials (MUAPs) generated by active MUs. The objectives of this study were to introduce a new adaptive spatio-temporal filter, here called maximum kurtosis filter (MKF), and to compare it with existing filters, on its performance to detect a single MUAP train from multichannel surface EMG signals. The MKF adaptively chooses the filter coefficients by maximising the kurtosis of the output. The proposed method was compared with five commonly used spatial filters, the weighted low-pass differential filter (WLPD) and the marginal distribution of a continuous wavelet transform. The performance was evaluated using simulated EMG signals. In addition, results from a multichannel surface EMG measurement fro from a subject who had been previously exposed to radiation due to cancer were used to demonstrate an application of the method. With five time lags of the MKF, the sensitivity was 98.7% and the highest sensitivity of the traditional filters was 86.8%, which was obtained with the WLPD. The positive predictivities of these filters were 87.4 and 80.4%, respectively. Results from simulations showed that the proposed spatio-temporal filtration technique significantly improved performance as compared with existing filters, and the sensitivity and the positive predictivity increased with an increase in number of time lags in the filter.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

Electromyography
EMG
Multichannel
Spatio-temporal filter
Kurtosis
Signal Processing
signalbehandling
MEDICINE

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Östlund, Nils
Yu, Jun, 1962-
Karlsson, Stefan
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
Artiklar i publikationen
Medical and Biol ...
Av lärosätet
Umeå universitet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy