A comparison between 8-bit and 10-bit luminance resolution when generating low-contrast sinusoidal test pattern on an LCD

Sund, Patrik (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Ungsten, L. (författare)
visa fler...
Månsson, Lars Gunnar, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa färre...
 (creator_code:org_t)
SPIE, 2007
2007
Engelska.
Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 6515
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Radiological images are today mostly displayed on monitors, but much is still unknown regarding the interaction between monitor and viewer. Issues like monitor luminance range, calibration, contrast resolution and luminance distribution need to be addressed further. To perform vision research of high validity to the radiologists, test images should be presented on medical displays. One of the problems has been how to display low contrast patterns in a strictly controlled way. This paper demonstrates how to generate test patterns close to the detection limit on a medical grade display using subpixel modulation. Patterns are generated with both 8-bit and 10-bit monitor input. With this technique, up to 7162 luminance levels can be displayed and the average separation is approximately 0.08 of a JND (Just Noticeable Difference) on a display with a luminance range between 1 and 400 cd/m2. These patterns were used in a 2AFC detection task and the detection threshold was found to be 0.75 ± 0.02 of a JND when the adaptation level was the same as the target luminance (20 cd/m2). This is a reasonable result considering that the magnitude of a JND is based on the method of adjustment rather than on a detection task. When test patterns with a different luminance than the adaptation level (20 cd/m2) were displayed, the detection thresholds were 1.11 and 1.06 of a JND for target luminance values 1.8 and 350 cd/m2, respectively.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Image display
Image perception
LCD
Low-contrast detection

Publikations- och innehållstyp

vet (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sund, Patrik
Båth, Magnus, 19 ...
Ungsten, L.
Månsson, Lars Gu ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk bildbe ...
Artiklar i publikationen
Progress in Biom ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy