SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:e6a55e8e-c6ea-40df-a3d9-dae69d8524bf"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:e6a55e8e-c6ea-40df-a3d9-dae69d8524bf" > Comparison of Radio...

Comparison of Radioimmunoprecipitation With Luciferase Immunoprecipitation for Autoantibodies to GAD65 and IA-2 beta

Burbelo, Peter D. (författare)
Hirai, Hiroki (författare)
Issa, Alexandra T. (författare)
visa fler...
Kingman, Albert (författare)
Lernmark, Åke (författare)
Lund University,Lunds universitet,Celiaki och diabetes,Forskargrupper vid Lunds universitet,Celiac Disease and Diabetes Unit,Lund University Research Groups
Ivarsson, Sten (författare)
Lund University,Lunds universitet,Pediatrisk endokrinologi,Forskargrupper vid Lunds universitet,Paediatric Endocrinology,Lund University Research Groups
Notkins, Abner L. (författare)
Iadarola, Michael J. (författare)
visa färre...
 (creator_code:org_t)
2010-01-19
2010
Engelska.
Ingår i: Diabetes Care. - : American Diabetes Association. - 1935-5548 .- 0149-5992. ; 33:4, s. 754-756
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE - To compare the sensitivity and specificity of luciferase immunoprecipitation (LIPS) with radioimmunoprecipitation (RIP) for the measurement of autoantibodies to the type 1 diabetes autoantigens glutamic acid decarboxylase 65 (GAD65) and insulinoma-associated protein (IA)-2 beta. RESEARCH DESIGN AND METHODS - Sera from 49 type 1 diabetic patients and 100 nondiabetic control subjects from Diabetes Antibody Standardization Program 2007 were used to screen for autoantibodies to GAD65. An additional 200 type 1 diabetic patients and 200 nondiabetic control subjects were used to validate the GAD65 results and screen for autoantibodies to IA-2 beta. RESULTS - LIPS showed equal sensitivity and specificity to RIP for detecting autoantibodies to GAD65 and IA-2 beta. Receiver-operating characteristic analysis revealed that the detection of autoantibodies to GAD65 and IA-2 beta by LIPS and RIP were not statistically different. CONCLUSIONS - The LIPS assay does not require the use of radioisotopes or in vitro transcription/translation and is a practical alternative at the clinical level for the RIP assay.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy