SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "onr:"swepub:oai:lup.lub.lu.se:5abc76a7-e371-4202-945e-9393908ba806" "

Sökning: onr:"swepub:oai:lup.lub.lu.se:5abc76a7-e371-4202-945e-9393908ba806"

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Rantakokko, Panu, et al. (författare)
  • A simple and fast liquid-liquid extraction method for the determination of 2,2 ',4,4 ',5,5 '-hexachlorobiphenyl (CB-153) and 1,1-dichloro-2,2-bis(p-chlorophenyl)-ethylene (p,p '-DDE) from human serum for epidemiological studies on type 2 diabetes
  • 2009
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673. ; 1216:6, s. 897-901
  • Tidskriftsartikel (refereegranskat)abstract
    • A simple and fast method is presented to be used for example in studies on the relationship between serum levels of persistent organic pollutants and type 2 diabetes mellitus. Method is based on liquid-liquid extraction and gas chromatography coupled with high.-resolution mass spectrometry. In the sample pretreatment special attention was paid to minimize the number of sample manipulation steps and the amounts of organic solvents needed. Compounds analyzed were 2,2',4,4',5,5'-hexachlorobiphenyl (PCB-153) and 1,1-dichloro-2,2-bis (p-chlorophenyl)-ethylene (p,p'-DDE), the major metabolite of DDT. The method included extraction and cleanup of 0.2 rill of serum in a single test tube and subsequent analysis of the extract from 0.2 ml final volume. Validation was conducted to explore the performance of the method. The limits of detection for p,p'-DDE and PCB-153 based on the standard deviation of the blank samples were 4.3 and 3.1 pg/ml, respectively. Repeatability was less than 2.5% at three concentration levels tested and recovery from Certified Reference Material SRM 1589a was 84% for p,p'-DDE and 87% for PCB-153 of the certified values, respectively. Serum samples from the AMAP intercalibration round 2008-2 were also analyzed, and results were 101-116% of the assigned values. The presented method was used for an epidemiological study with more than 700 serum samples from a type 2 diabetes cohort from Sweden. (C) 2008 Elsevier B.V. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Rylander, Lars (1)
Rignell-Hydbom, Anna (1)
Kiviranta, Hannu (1)
Rantakokko, Panu (1)
Vartiainen, Terttu (1)
Lärosäte
Lunds universitet (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy