Sökning: onr:"swepub:oai:DiVA.org:du-38877" >
Single versus pairw...
Single versus pairwise interpretation of cardiotochography, a comparative study from six Swedish delivery units
-
- Åmark, H. (författare)
- Karolinska Institutet
-
- Millde-Luthander, C. (författare)
- Karolinska Institutet
-
- Ajne, G. (författare)
- Department of Obstetrics and Gynecology, Karolinska University Hospital, Huddinge, Stockholm, Sweden
-
visa fler...
-
- Högberg, Ulf, 1949- (författare)
- Uppsala universitet,Obstetrik & gynekologi
-
- Pettersson, H. (författare)
- Karolinska Institutet
-
- Wiklund, Ingela (författare)
- Karolinska Institutet,Division of Obstetrics and Gynecology, Karolinska Institutet, Danderyd Hospital
-
- Grunewald, C. (författare)
- Karolinska Institutet
-
visa färre...
-
(creator_code:org_t)
- Elsevier, 2014
- 2014
- Engelska.
-
Ingår i: Sexual & Reproductive HealthCare. - : Elsevier. - 1877-5756 .- 1877-5764. ; 5:4, s. 195-198
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective: The aim of the study was to evaluate whether interpreting CTG pairwise brings about a higher level of correctly classified CTG recordings in a non-selected population of midwives and physicians. Study design: A comparative study. Setting: Five delivery units in Stockholm and one delivery unit in Uppsala, with 1589, 3740, 3908, 4539, 6438, and 7331 deliveries in 2011, respectively. Subjects: 536 midwives and physicians classified one randomly selected CTG recording individually followed by a pairwise classification. The pairs consisted of two midwives (119 pairs) or one midwife and one physician (149 pairs), a total of 268 pairs. Main outcome measure: The proportion of individually correctly classified CTG recordings versus the proportion of pairwise correctly classified CTG recordings. Results: The proportion of individually correctly classified CTG's was 75% and the proportion of pairwise correctly classified CTG's was 80% (difference 5%, p = 0.12). Conclusions: There was no statistically significant difference when CTG's were classified pairwise compared to individual classifications. The proportion of individually correctly classified CTG's was high (75%). There were differences in the proportion of correctly classified CTG recordings between the delivery units, indicating potential areas of improvement. © 2014 Elsevier B.V.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Reproduktionsmedicin och gynekologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Obstetrics, Gynaecology and Reproductive Medicine (hsv//eng)
Nyckelord
- Cardiotocography
- Cardiotocography interpretation
- Fetal surveillance
- Intrapartum
- Pairwise interpretation
- Article
- comparative study
- delivery
- human
- midwife
- physician
- priority journal
- Sweden
- delivery room
- female
- health service
- obstetrics
- pregnancy
- procedures
- standards
- Delivery Rooms
- Delivery
- Obstetric
- Health Services
- Humans
- Midwifery
- Physicians
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas