SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:hj-63331"
 

Sökning: onr:"swepub:oai:DiVA.org:hj-63331" > Assessment of left ...

Assessment of left ventricular diastolic function from mitral annulus motion, a comparison with pulsed Doppler measurements in patients with heart failure

Blomstrand, Peter (författare)
Department of Clinical Physiology, Linköping Heart Centre, University of Linköping, Sweden; Department of Clinical Physiology, Länssjukuset Ryhov, Jönköping, Sweden
Kongstad, O. (författare)
Department of Cardiology, Linköping Heart Centre, University of Linköping, Sweden
Broqvist, M. (författare)
Department of Cardiology, Linköping Heart Centre, University of Linköping, Sweden
visa fler...
Dahlström, U. (författare)
Department of Cardiology, Linköping Heart Centre, University of Linköping, Sweden
Wranne, B. (författare)
Department of Clinical Physiology, Linköping Heart Centre, University of Linköping, Sweden
visa färre...
 (creator_code:org_t)
John Wiley & Sons, 1996
1996
Engelska.
Ingår i: Clinical Physiology. - : John Wiley & Sons. - 0144-5979 .- 1365-2281. ; 16:5, s. 483-493
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Mitral and pulmonary venous flow velocity recordings are often used for the assessment of left ventricular diastolic function. These curves are, however, also influenced by other factors. To investigate whether mitral annulus motion carries additional information in this context, mitral annulus motion was compared to Doppler registrations of mitral and pulmonary flow velocities in 38 patients with heart failure (NYHA II-III) after myocardial infarction. Patients with an increased atrial contribution to mitral annulus motion (> 57%, n = 12) had a higher mitral late-to-early flow velocity ratio (A/E) and pulmonary systolic to diastolic filling ratio (< 0.01). Patients with atrial displacement above average for the group (≤ 5.1 mm, n = 19) had a higher mitral A/E ratio and pulmonary systolic to diastolic filling ratio than patients with a lower than average atrial component (P < 0.05). There was a significant correlation between a/T ratio and A/E ratio (r = 0.61, P < 0.001) and between pulmonary flow and transmitral flow (= 0.76, P < 0.001). We conclude that an increased atrial displacement of the mitral annulus is a frequent finding in patients with signs of left ventricular relaxation abnormality. There is a significant correlation between a/T ratio and A/E ratio but the information contained in the two indices are not identical.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Left ventricular diastolic function
Mitral annulus motion
Pulmonary venous flow
Transmitral flow
adult
aged
article
blood flow velocity
clinical article
correlation function
Doppler echocardiography
female
heart failure
heart infarction
heart left ventricle function
heart ventricle filling
human
intermethod comparison
M mode echocardiography
male
mitral valve
priority journal
pulmonary vein
vein blood flow

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Blomstrand, Pete ...
Kongstad, O.
Broqvist, M.
Dahlström, U.
Wranne, B.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Jönköping University

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy