SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:hkr-20381"
 

Sökning: onr:"swepub:oai:DiVA.org:hkr-20381" > Detection of F8 int...

Detection of F8 int22h inversions using digital droplet PCR and mile-post assays

Manderstedt, Eric (författare)
Kristianstad University,Högskolan Kristianstad,Avdelningen för miljö- och biovetenskap,Forskningsmiljön Biomedicin
Lind-Halldén, Christina (författare)
Kristianstad University,Högskolan Kristianstad,Forskningsmiljön Biomedicin,Avdelningen för miljö- och biovetenskap
Ljung, Rolf (författare)
Lund University,Lunds universitet,Pediatrik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Pediatrisk hematologi,Forskargrupper vid Lunds universitet,Paediatrics (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Paediatric Haematology Research Unit,Lund University Research Groups,Skåne University Hospital
visa fler...
Astermark, Jan (författare)
Skåne University Hospital
Halldén, C (författare)
Högskolan Kristianstad,Avdelningen för Naturvetenskap,Forskningsmiljön Biomedicin
Halldén, Christer (författare)
Kristianstad University
visa färre...
 (creator_code:org_t)
Wiley-Blackwell, 2020
2020
Engelska.
Ingår i: Journal of Thrombosis and Haemostasis. - : Wiley-Blackwell. - 1538-7933 .- 1538-7836. ; 8:5, s. 1039-1049
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Inversions involving intron 22 (Inv22) of F8 are detected in approximately 45% of all severe hemophilia A patients. Diagnosis is complicated by the large size of the ~9.5 kb int22h repeated sequence which generates the inversions. Methods such as long-range PCR and inverse-shifting PCR are currently used diagnostically, but suffer from low PCR efficiencies and are difficult to standardize.OBJECTIVES: To design and validate a sensitive and robust assay for the detection of F8 int22h inversions.METHODS: Digital droplet PCR using mile-post assays was used to investigate archival DNA samples.RESULTS: The detection of linkage as a function of physical distance between loci was investigated using an anchor locus and mile-post loci located at 1, 6, 12 and 15 kb distances from the anchor locus. The proportion of linked molecules decreased with increasing distance between loci and showed 30-40% linked molecules for loci 12-15 kb apart. Mile-post assays specific for wild type and Inv22 type 1 and 2 chromosomes were then designed and optimized. All three assays showed high specificities and sensitivities, with coefficients of variation < 5% for all assays. Analysis of 106 patients and 20 carrier mothers showed complete concordance with previously known mutation status. The analysis demonstrated the robustness of the assays versus input DNA concentration (6 ng and higher) and level of fragmentation.CONCLUSIONS: Digital droplet PCR and mile-post assays can be used to detect F8 int22h inversions. The assay systems are technically simple to perform, highly efficient and robust.

Ämnesord

MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Hematologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Hematology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

Factor VIII
Genetic Linkage
Hemophilia A
Polymerase Chain Reaction
Sequence Inversion

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy