SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:hv-17562"
 

Sökning: onr:"swepub:oai:DiVA.org:hv-17562" > Effect of thermal m...

Effect of thermal management approaches on geometry and productivity of thin-walled structures of er 5356 built by wire + arc additive manufacturing

da Silva, Leandro João (författare)
Center for Research and Development of Welding Processes (Laprosolda), Department of Mechanical Engineering, Federal University of Uberlandia (UFU), Uberlândia (BRA)
Ferraresi, Henrique Nardon (författare)
Center for Research and Development of Welding Processes (Laprosolda), Department of Mechanical Engineering, Federal University of Uberlandia (UFU), Uberlândia (BRA)
Araújo, Douglas Bezerra (författare)
Center for Research and Development of Welding Processes (Laprosolda), Department of Mechanical Engineering, Federal University of Uberlandia (UFU), Uberlândia (BRA)
visa fler...
Reis, Reis Pablo (författare)
Center for Research and Development of Welding Processes (Laprosolda), Department of Mechanical Engineering, Federal University of Uberlandia (UFU), Uberlândia (BRA)
Scotti, Americo, 1955- (författare)
Högskolan Väst,Avdelningen för svetsteknologi (SV),Center for Research and Development of Welding Processes (Laprosolda), Department of Mechanical Engineering, Federal University of Uberlandia (UFU), Uberlândia (BRA),PTW
visa färre...
 (creator_code:org_t)
2021-09-20
2021
Engelska.
Ingår i: Coatings. - : MDPI. - 2079-6412. ; 11:9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The present paper aimed at assessing the effect of two thermal management approaches on geometry and productivity of thin-walled structures built by Wire + Arc Additive Manufacturing (WAAM). Thin-walls of ER 5356 (Al5Mg) with different lengths and the same number of layers were deposited via the gas metal arc (GMA) process with the aid of an active cooling technique (near-immersion active cooling-NIAC) under a fixed set of deposition parameters. Then, the same experiment was performed with natural cooling (NC) in air. To characterize the thermal management approaches, the interpass temperature (i.e., the temperature at which subsequent layers are deposited) were monitored by a trailing/leading infrared pyrometer during the deposition time. Finally, thin walls with a fixed length were deposited using the NC and NIAC approaches with equivalent interpass temperatures. As expected, the shorter the wall length the more intense the deposition concentration, heat accumulation, and, thus, geometric deviation. This behavior was more evident and premature for the NC strategy due to its lower heat sinking effectiveness. The main finding was that, regardless of the thermal management technique applied, if the same interpass temperature is selected and maintained, the geometry of the part being built tends to be stable and very similar. However, the total deposition time is somewhat shorter with the NIAC technique due its greater heat sinking advantage. Thus, the NIAC technique facilitates the non-stop manufacturing of small parts and details via WAAM. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Bearbetnings-, yt- och fogningsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Manufacturing, Surface and Joining Technology (hsv//eng)

Nyckelord

directed energy deposition; wire + arc additive manufacturing; cold metal transfer; thin-walled structures; thermal management; part geometry; production time
Production Technology
Produktionsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Coatings (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy