Sökning: onr:"swepub:oai:DiVA.org:kau-16970" > Application of Plas...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 02708naa a2200361 4500 | |
001 | oai:DiVA.org:kau-16970 | |
003 | SwePub | |
008 | 130121s1986 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-169702 URI |
024 | 7 | a https://doi.org/10.1002/bms.12001312092 DOI |
040 | a (SwePub)kau | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Roepstorff, P.u Department of Molecular Biology, Odense University, Denmark4 aut |
245 | 1 0 | a Application of Plasma Desorption Mass Spectrometry to Molecular Weight Determination of Structural Protein from Insect Cuticle |
264 | 1 | b Wiley,c 1986 |
338 | a print2 rdacarrier | |
520 | a During sequence determination of a structural protein from the cuticle of the migratory locust, Locusta migratoria, a discrepancy was found between the molecular weight calculated from the sequence data (15 323) and that estimated by SDS-gel electrophoresis (21 600). The protein contains several repeated sequences, and the discrepancy might indicate that part of the sequence was missing or that the protein contained a large prosthetic group. The molecular weight of the protein was determined by 127I-plasma desorption mass spectrometry to be 15 329±50 which confirms the sequence data and shows the molecular weight determination based on SDS-electrophoresis to be too high. | |
650 | 7 | a NATURVETENSKAPx Biologix Biokemi och molekylärbiologi0 (SwePub)106022 hsv//swe |
650 | 7 | a NATURAL SCIENCESx Biological Sciencesx Biochemistry and Molecular Biology0 (SwePub)106022 hsv//eng |
700 | 1 | a Højrup, P.u Department of Molecular Biology, Odense University, Denmark4 aut |
700 | 1 | a Sundqvist, B.U.R.u Tandem Accelerator Laboratory, Uppsala University4 aut |
700 | 1 | a Jonsson, Gunnaru Tandem Accelerator Laboratory, Uppsala University4 aut0 (Swepub:kau)gunnjons |
700 | 1 | a Håkansson, P.u Tandem Accelerator Laboratory, Uppsala University4 aut |
700 | 1 | a Andersson, S. O.u Institute for Biological Chemistry A, University of Copenhagen, Denmark4 aut |
700 | 1 | a Johansson, K. E.u Mycoplasma Laboratory, The National Veterinary Institute, Uppsala4 aut |
710 | 2 | a Department of Molecular Biology, Odense University, Denmarkb Tandem Accelerator Laboratory, Uppsala University4 org |
773 | 0 | t Journal of Mass Spectrometryd : Wileyg 13:12, s. 689-691q 13:12<689-691x 1076-5174x 1096-9888 |
773 | 0 | t Biological Mass Spectrometryd : Wileyg 13:12, s. 689-691q 13:12<689-691x 1052-9306 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-16970 |
856 | 4 8 | u https://doi.org/10.1002/bms.1200131209 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy