245 | 1 0 | a Contrast-enhanced spectral mammography with a photon-counting detector |
264 | c 2010-04-12 | |
264 | 1 | b Wiley,c 2010 |
338 | a electronic2 rdacarrier | |
500 | a QC 20100714 ändrad från submitted till published 20110103 | |
520 | a Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. In particular, the detectability of a contrast agent can be improved over a lumpy background. We have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved imaging was studied.Methods: A framework for system characterization was set up that included quantum and anatomical noise, and a theoretical model of the system was benchmarked to phantom measurements.Results: It was found that optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, and an ideal-observer detectability index could be improved more than a factor of two compared to absorption imaging in the phantom study. In the clinical case, an improvement close to 80% was predicted for an average glandularity breast, and a factor of eight for dense breast tissue. Another 70% was found to be within reach for an optimized system.Conclusions: Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Annan teknikx Övrig annan teknik0 (SwePub)211992 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Other Engineering and Technologiesx Other Engineering and Technologies not elsewhere specified0 (SwePub)211992 hsv//eng |
650 | 7 | a NATURVETENSKAPx Data- och informationsvetenskapx Datorseende och robotik0 (SwePub)102072 hsv//swe |
650 | 7 | a NATURAL SCIENCESx Computer and Information Sciencesx Computer Vision and Robotics0 (SwePub)102072 hsv//eng |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk laboratorie- och mätteknik0 (SwePub)206012 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Laboratory and Measurements Technologies0 (SwePub)206012 hsv//eng |
653 | a spectral imaging | |
653 | a mammography | |
653 | a contrast agent | |
653 | a photon counting | |
653 | a dual-energy subtraction | |
653 | a energy weighting | |
653 | a anatomical noise | |
653 | a Other engineering physics | |
653 | a Övrig teknisk fysik | |
653 | a Image analysis | |
653 | a Bildanalys | |
653 | a Radiological research | |
653 | a Radiologisk forskning | |
653 | a Medical engineering | |
653 | a Medicinsk teknik | |
700 | 1 | a Hemmendorff, Magnus4 aut |
700 | 1 | a Cederström, Björnu KTH,Medicinsk bildfysik,Medical Imaging4 aut0 (Swepub:kth)u1oerth9 |
700 | 1 | a Åslund, Magnus4 aut |
700 | 1 | a Danielsson, Matsu KTH,Medicinsk bildfysik,Medical Imaging4 aut0 (Swepub:kth)u1m3qe0f |
710 | 2 | a KTHb Medicinsk bildfysik4 org |
773 | 0 | t Medical physics (Lancaster)d : Wileyg 37:5, s. 2017-2029q 37:5<2017-2029x 0094-2405 |
856 | 4 | u https://kth.diva-portal.org/smash/get/diva2:278575/FULLTEXT01.pdfx primaryx Raw objecty fulltext:postprint |
856 | 4 | u http://kth.diva-portal.org/smash/get/diva2:278575/FULLTEXT01 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-11637 |
856 | 4 8 | u https://doi.org/10.1118/1.3371689 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy