Sökning: onr:"swepub:oai:DiVA.org:kth-116567" >
Peak and off-peak o...
Peak and off-peak operations of the air separatino unit in oxy-fuel combustion power generation systems
-
- Hu, Yukun (författare)
- KTH,Energiprocesser,Royal Institute of Technology
-
- Li, Xun (författare)
- Tianjin University, School of Mechanical Engineering, China
-
- Li, Hailong (författare)
- Mälardalens högskola,Akademin för ekonomi, samhälle och teknik
-
visa fler...
-
- Yan, Jinyue (författare)
- Mälardalens högskola,KTH,Energiprocesser,Akademin för ekonomi, samhälle och teknik
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2013
- 2013
- Engelska.
-
Ingår i: Applied Energy. - : Elsevier BV. - 0306-2619 .- 1872-9118. ; 112:SI, s. 747-754
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Introducing CO2 capture and storage (CCS) into the power systems requires the re-investigation of the load balance for the electrical grid. For the oxy-coal combustion capture technology, the energy use of ASU can be shifted between the peak-load and off-peak-load periods, which may bring more benefits. In this paper, peak and off-peak (POP) operations for the air separation unit (ASU) with liquid oxygen storage were studied based on a 530 MW coal-fired power system. According to the simulation results, the oxy-coal combustion power system running POP is technically feasible that it can provide a base load of 496 MW during the off-peak period and a peak load of 613 MW during the peak period. And the equivalent efficiency of the power system running POP is only 0.3% lower than the one not running POP. Moreover, according to the economic assessments based on the net present value, it is also economically feasible that the payback time of the investment of the oxy-coal combustion power system running POP is about 13 years under the assumptions of 10% discount rate and 2.5% cost escalation rate. In addition, the effects of the difference of on-grid electricity prices, daily peak period, investment for POP operations, and ASU energy consumption were also analyzed, concerning the net present value.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Kemiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Chemical Engineering (hsv//eng)
Nyckelord
- Oxy-coal combustion
- Air separation unit (ASU)
- Peak and off-peak operations
- CO2 capture
- Economic assessment
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas