SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-149960"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-149960" > Embodied greenhouse...

  • Brown, Nils W. O.KTH,Miljöstrategisk analys (fms) (författare)

Embodied greenhouse gas emissions from refurbishment of residential building stock to achieve a 50% operational energy reduction

  • Artikel/kapitelEngelska2014

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2014
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-149960
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-149960URI
  • https://doi.org/10.1016/j.buildenv.2014.04.018DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20140908
  • Mitigating climate change through operational energy reduction in existing buildings is of highest priority for policy-makers in Europe and elsewhere. At the same time there is increasing understanding of the significance of impacts arising from material production for buildings. The aim of this work has therefore been to evaluate the importance of embodied GWP for refurbishment for operational energy reduction on a stockwide basis. It is further intended to judge the relative significance of embodied GWP for specific refurbishment measures implemented for operational energy reduction. We study the case of operational energy reduction in the Swedish residential building stock by 50% compared to 1995. The total embodied GWP to achieve the noted operational energy reduction is 0.35 Mt CO2-e/year. 83% of this total is due to ventilation and window measures alone. Compared with previous studies assessing GWP mitigation from operational energy reduction, the "GWP payback time" is just over 3 years. Many types of measure that contribute significantly to achieving the above operational energy goal had average embodied GWP between 10 and 20 g CO2-e/kW h operational energy reduction, notably window and ventilation measures. Indoor temperature reduction (to 20 degrees C), was also significant for stockwide operational energy reduction but had a very low GWP of 0.4 g CO2-e/kW h operational energy reduction. If this measure proves unfeasible to implement on a stockwide basis then more expensive measures with higher embodied GWP will be needed to achieve the stated energy reduction goal.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Olsson, StefanKTH,Miljöstrategisk analys (fms)(Swepub:kth)u1q16e3f (författare)
  • Malmqvist, ToveKTH,Miljöstrategisk analys (fms)(Swepub:kth)u18h1n9h (författare)
  • KTHMiljöstrategisk analys (fms) (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Building and Environment: Elsevier BV79, s. 46-560360-13231873-684X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Brown, Nils W. O ...
Olsson, Stefan
Malmqvist, Tove
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
Artiklar i publikationen
Building and Env ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy