SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-154770"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-154770" > DYNAMIC MR IMAGING,...

DYNAMIC MR IMAGING, BIODISTRIBUTION AND PHARMACOKINETICS OF POLYMER SHELLED MICROBUBBLES CONTAINING SPION

Barrefelt, Åsa (författare)
Karolinska Institutet
Paradossi, Gaio (författare)
Asem, Heba (författare)
KTH,Funktionella material, FNM
visa fler...
Margheritelli, Silvia (författare)
Saghafian, Maryam (författare)
Oddo, Letizia (författare)
Muhammed, Mamoun (författare)
Karolinska Institutet,KTH,Funktionella material, FNM
Aspelin, Peter (författare)
Karolinska Institutet
Hassan, Moustapha (författare)
Brismar, Torkel B. (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: NANO. - 1793-2920. ; 9:6, s. 1450069-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Magnetic Resonance Imaging (MRI) is a noninvasive diagnostic method that provides information on morphological and physiological changes of the internal organs over time. Imaging and measurements can be repeated on the same subject, thereby reducing inter-individual variability effects and hence the number of subjects required. A potential MRI contrast agent consisting of microbubbles embedded with superparamagnetic iron oxide nanoparticles (SPION) in the shell (SPION MBs) was injected intravenously into rats to determine their biodistribution and pharmacokinetics using MR imaging. Agarose phantoms containing SPION MBs were scanned using 3 T MRI to construct a standard curve. Rats were injected with SPION MBs, free SPION or plain MBs and scanned dynamically at 3 T using a clinical MR scanner. The relaxation rate (R2*) was studied over time as a measure of the iron oxide concentrations to enable calculation of the pharmacokinetic parameters. The kinetics of SPION MBs in the liver was fitted to a one-compartment model. Furthermore, the biological fate of SPION MBs was examined via a histological survey of tissue samples using Perls' Prussian blue staining and immunohistochemistry (IHC). 1.2 h after injection of SPION MBs, T2* of the liver had decreased to its minimum. The elimination half-life of SPION MBs was 598.2 +/- 97.3 h, while the half-life for SPION was 222.6 +/- 26.4 h. Moreover, our study showed that SPION MBs were taken up by the macrophages in the lungs, spleen and liver. MBs labeled with SPION can be used for MR imaging. Moreover, MRI is a reliable and noninvasive tool that can be utilized in pharmacokinetic investigations of future contrast agents using SPION MBs and SPION in the rat.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

Magnetic resonance imaging
dynamic MR imaging
microbubbles
SPION
superparamagnetic iron oxide nanoparticles
pharmacokinetics
biodistribution

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • NANO (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy