Energetic and exergetic analysis of a low- Temperature based district heating substation for low energy buildings

Castro Flores, José Fiacro (författare)
KTH,Energiteknik
Chiu, Justin Ningwei (författare)
KTH,Energiteknik
Le Corre, O. (författare)
visa fler...
Lacarrière, B. (författare)
Martin, Viktoria (författare)
KTH,Energiteknik
visa färre...
 (creator_code:org_t)
International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, 2015
2015
Engelska.
Ingår i: ECOS 2015 - 28th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems. - : International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems. - 9782955553909
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • District Heating (DH) technology contributes to the low GHG emissions energy system, facilitates a renewable energy usage, and increases the overall system efficiency, while providing the necessary heating services to the built environment. However, the existing DH technology may not be technically and economically effective to service buildings with low-energy demands. Here, low- Temperature based district heating (LTDH) provides a better match between supply and demand in terms of energy quality. This paper deals with the energy and exergy analyses of a LTDH substation supplying a secondary LTDH network as a subnet of the existing DH system. The substation is supplied with a mix of supply and return flows from the main DH network. An energy and exergy analysis was employed based on modelling and simulation to compare the performance of two proposed substation configurations to that of a conventional DH substation operating at low- Temperature. The study was performed for a year round outdoor temperatures scenario under steady-state conditions. The exergy destruction at the system components was identified and compared. The results of this analysis show that by using the low- Temperature flow from the DH return pipe, the final exergy efficiency of the overall system is increased. On the other hand, assuming an adiabatic system the energy performance stays the same. As compared with the conventional DH network, the integration of the proposed LTDH substation reduced the share of energy demand covered by the main DH supply by 20-25% and improved the overall exergy efficiency from 79% to 85-87% depending on the substation configuration. Based on the results, the solution presented is seen as an effective approach to reduce the system's losses, and to increase the quality match between the low-energy heating demands and the supply.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

District heating
Efficiency
Exergy
Low temperature
Substation
Temperature cascading
Economic and social effects
Economics
Environmental impact
Greenhouse gases
Heating
Temperature
Energetic and exergetic analysis
Energy and exergy analysis
Low energy buildings
Low temperatures
Modelling and simulations
Steady-state condition
Substation configurations
Energy efficiency

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy