SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-207654"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-207654" > Optimization of a r...

  • Campana, Pietro EliaMälardalens högskola,Framtidens energi (författare)

Optimization of a residential district with special consideration on energy and water reliability

  • Artikel/kapitelEngelska2017

Förlag, utgivningsår, omfång ...

  • ELSEVIER SCI LTD,2017
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-207654
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-207654URI
  • https://doi.org/10.1016/j.apenergy.2016.10.005DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-34033URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20170602
  • Many cities around the world have reached a critical situation when it comes to energy and water supply, threatening the urban sustainable development. From an engineering and architecture perspective it is mandatory to design cities taking into account energy and water issues to achieve high living and sustainability standards. The aim of this paper is to develop an optimization model for the planning of residential urban districts with special consideration of renewables and water harvesting integration. The optimization model is multi-objective which uses a genetic algorithm to minimize the system life cycle costs, and maximize renewables and water harvesting reliability through dynamic simulations. The developed model can be used for spatial optimization design of new urban districts. It can also be employed for analyzing the performances of existing urban districts under an energy-water-economic viewpoint. The optimization results show that the reliability of the hybrid renewables based power system can vary between 40 and 95% depending on the scenarios considered regarding the built environment area and on the cases concerning the overall electric load. The levelized cost of electricity vary between 0.096 and 0.212 $/kW h. The maximum water harvesting system reliability vary between 30% and 100% depending on the built environment area distribution. For reliabilities below 20% the levelized cost of water is kept below 1 $/m(3) making competitive with the network water tariff.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Quan, Steven JigeGeorgia Institute of Technology, US (författare)
  • Robbio, Federico IgnacioABB AB, Västerås, Sweden (författare)
  • Lundblad, AndersMälardalens högskola,KTH,Energiprocesser,Framtidens energi,KTH Royal Institute of Technology, Sweden(Swepub:mdh)ald03 (författare)
  • Zhang, YangKTH,Energiprocesser,KTH Royal Institute of Technology, Sweden(Swepub:kth)u1zafljf (författare)
  • Ma, TaoShanghai Jiao Tong University, China (författare)
  • Karlsson, BjörnMälardalens högskola,Framtidens energi(Swepub:mdh)bkn04 (författare)
  • Yan, Jinyue,1959-Mälardalens högskola,KTH,Kemiteknik,Framtidens energi(Swepub:mdh)jyn01 (författare)
  • Mälardalens högskolaFramtidens energi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Applied Energy: ELSEVIER SCI LTD194, s. 751-7640306-26191872-9118

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy