Initial in-vitro trial for intra-cranial pressure monitoring using subdermal proximity-coupled split-ring resonator
-
- Redzwan, Syaiful (författare)
- Uppsala universitet,Fasta tillståndets elektronik
-
- Velander, Jacob (författare)
- Uppsala universitet,Fasta tillståndets elektronik
-
- Perez, Mauricio D. (författare)
- Uppsala universitet,Fasta tillståndets elektronik
-
visa fler...
-
- Asan, Noor Badariah, 1984- (författare)
- Uppsala universitet,Fasta tillståndets elektronik
-
- Rajabi, Mina (författare)
- KTH,Mikro- och nanosystemteknik,KTH Royal Inst Technol, Sch Elect Engn, Dept Micro & Nanosyt, Stockholm, Sweden
-
- Niklaus, Frank, 1971- (författare)
- KTH,Mikro- och nanosystemteknik,KTH Royal Inst Technol, Sch Elect Engn, Dept Micro & Nanosyt, Stockholm, Sweden
-
- Nowinski, Daniel (författare)
- Uppsala universitet,Plastikkirurgi
-
- Lewén, Anders, 1965- (författare)
- Uppsala universitet,Enblad: Neurokirurgi
-
- Enblad, Per (författare)
- Uppsala universitet,Enblad: Neurokirurgi
-
- Augustine, Robin, 1982- (författare)
- Uppsala universitet,Fasta tillståndets elektronik
-
visa färre...
-
(creator_code:org_t)
- Institute of Electrical and Electronics Engineers (IEEE), 2018
- 2018
- Engelska.
-
Ingår i: IMBioc 2018 - 2018 IEEE/MTT-S International Microwave Biomedical Conference. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781538659182 ; , s. 73-75
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Intra cranial pressure (ICP) monitoring is used in treating severe traumatic brain injury (TBI) patients. All current clinical available measurement methods are invasive presenting considerable social costs. This paper presents a preliminary investigation of the feasibility of ICP monitoring using an innovative microwave-based non-invasive approach. A phantom mimicking the dielectric characteristics of human tissues of the upper part of the head at low microwave frequencies is employed together to a proof-of-concept prototype based on the proposed approach consisting in a readout system and a sub-dermally implanted passive device, both based in split ring resonator techniques. This study shows the potential of our approach to detect two opposite pressure variation stages inside the skull. The employed phantom model needs to be improved to support finer variations in the pressure and better phantom parts, principally for the skull mimic and the loss tangent of all mimics.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Annan medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Other Medical Engineering (hsv//eng)
Nyckelord
- Biocompatible
- Intra cranial pressure
- Microwave technique
- Split ring resonator (SRR) sensor
Publikations- och innehållstyp
- ref (ämneskategori)
- kon (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Redzwan, Syaiful
-
Velander, Jacob
-
Perez, Mauricio ...
-
Asan, Noor Badar ...
-
Rajabi, Mina
-
Niklaus, Frank, ...
-
visa fler...
-
Nowinski, Daniel
-
Lewén, Anders, 1 ...
-
Enblad, Per
-
Augustine, Robin ...
-
visa färre...
- Om ämnet
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Medicinteknik
-
och Annan medicintek ...
- Artiklar i publikationen
-
IMBioc 2018 - 20 ...
- Av lärosätet
-
Kungliga Tekniska Högskolan
-
Uppsala universitet