Sökning: onr:"swepub:oai:DiVA.org:kth-240783" >
Automated analysis ...
Automated analysis of fetal cardiac function using color tissue Doppler imaging
-
- Herling, L. (författare)
- Karolinska Institutet
-
- Johnson, Jonas (författare)
- Karolinska Institutet,KTH,Medicinsk teknik,Karolinska Univ Hosp, Dept Obstet & Gynecol, Ctr Fetal Med, Stockholm, Sweden
-
- Ferm-Widlund, K. (författare)
- Karolinska Univ Hosp, Dept Obstet & Gynecol, Ctr Fetal Med, Stockholm, Sweden.
-
visa fler...
-
- Bergholm, Fredrik (författare)
- KTH,Medicinsk teknik
-
- Lindgren, P. (författare)
- Karolinska Institutet
-
- Sonesson, S. -E (författare)
- Karolinska Institutet
-
- Acharya, G. (författare)
- Karolinska Institutet
-
- Westgren, M. (författare)
- Karolinska Institutet
-
visa färre...
-
(creator_code:org_t)
- 2018-10-01
- 2018
- Engelska.
-
Ingår i: Ultrasound in Obstetrics and Gynecology. - : Wiley. - 0960-7692 .- 1469-0705. ; 52:5, s. 599-608
- Relaterad länk:
-
https://obgyn.online...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective To evaluate the feasibility of automated analysis of fetal myocardial velocity recordings obtained by color tissue Doppler imaging (cTDI). Methods This was a prospective cross-sectional observational study of 107 singleton pregnancies >= 41 weeks of gestation. Myocardial velocity recordings were obtained by cTDI in a long-axis four-chamber view of the fetal heart. Regions of interest were placed in the septum and the right (RV) and left (LV) ventricular walls at the level of the atrioventricular plane. Peak myocardial velocities and mechanical cardiac time intervals were measured both manually and by an automated algorithm and agreement between the two methods was evaluated. Results In total, 321 myocardial velocity traces were analyzed using each method. It was possible to analyze all velocity traces obtained from the LV, RV and septal walls with the automated algorithm, and myocardial velocities and cardiac mechanical time intervals could be measured in 96% of all traces. The same results were obtained when the algorithm was run repeatedly. The myocardial velocities measured using the automated method correlated significantly with those measured manually. The agreement between methods was not consistent and some cTDI parameters had considerable bias and poor precision. Conclusions Automated analysis of myocardial velocity recordings obtained by cTDI was feasible, suggesting that this technique could simplify and facilitate the use of cTDI in the evaluation of fetal cardiac function, both in research and in clinical practice.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Reproduktionsmedicin och gynekologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Obstetrics, Gynaecology and Reproductive Medicine (hsv//eng)
Nyckelord
- automated analysis
- fetal cardiac function
- fetal echocardiography
- mechanical time intervals
- myocardial velocities
- TDI
- tissue Doppler imaging
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas