SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-296401"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-296401" > On the Development ...

On the Development of a Novel Contrast Pulse Sequence for Polymer-Shelled Microbubbles

Chen, Hongjian (författare)
KTH,Medicinsk avbildning
Evangelou, Dimitrios (författare)
KTH,Medicinteknik och hälsosystem,Dept Biomed Engn & Hlth Syst, S-14152 Stockholm, Sweden.
Loskutova, Ksenia (författare)
KTH,Medicinsk avbildning
visa fler...
Ghorbani, Morteza (författare)
KTH,Medicinsk avbildning,Sabanci Univ, Nanotechnol Res & Applicat Ctr, TR-34956 Istanbul, Turkey.
Grishenkov, Dmitry, Associate Professor, 1983- (författare)
KTH,Medicinsk avbildning,Karolinska Inst, Dept Clin Sci Intervent & Technol, S-14152 Stockholm, Sweden.;Karolinska Univ Hosp, Dept Clin Physiol, S-17177 Stockholm, Sweden.
visa färre...
 (creator_code:org_t)
Institute of Electrical and Electronics Engineers (IEEE), 2021
2021
Engelska.
Ingår i: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - : Institute of Electrical and Electronics Engineers (IEEE). - 0885-3010 .- 1525-8955. ; 68:5, s. 1569-1579
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Contrast agents are routinely used in ultrasound examinations. Nonlinear ultrasound imaging techniques have been developed over decades to enhance the contrast between the tissue and the blood pool after the injection of ultrasound contrast agents (UCAs). In this study, we introduce a new contrast pulse sequence, CPS4. The CPS4 combines pulse inversion (PI), subharmonic (SH), and ultraharmonic (UH) techniques to remove propagation distortion while capturing the unique SH and UH responses from UCAs. The novel CPS4 and conventional PI, SH, and UH techniques were used to detect the presence of a research-grade, thick-shell, polymer microbubble in a tissue-mimicking flow phantom. The contrast-to-tissue ratios (CTRs) obtained from the applications of all techniques were compared. The results show that the highest CTR of approximately 16 dB was obtained using CPS4, which was superior to the individual reference techniques: PI, SH, and UH techniques, in all scenarios considered in this study.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

Ultrasonic imaging
Imaging
Transducers
Finite impulse response filters
Band-pass filters
Phantoms
Optical filters
Contrast pulse sequence
medical imaging
ultrasound contrast agents (UCAs)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy