Sökning: onr:"swepub:oai:DiVA.org:kth-325236" > Multi-marker profil...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 04864naa a2200541 4500 | |
001 | oai:DiVA.org:kth-325236 | |
003 | SwePub | |
008 | 230403s2023 | |||||||||||000 ||eng| | |
009 | oai:DiVA.org:uu-500017 | |
009 | oai:prod.swepub.kib.ki.se:152073271 | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-3252362 URI |
024 | 7 | a https://doi.org/10.1016/j.bios.2023.1151422 DOI |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-5000172 URI |
024 | 7 | a http://kipublications.ki.se/Default.aspx?queryparsed=id:1520732712 URI |
040 | a (SwePub)kthd (SwePub)uud (SwePub)ki | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Sahu, Siddharth S.u KTH,Tillämpad fysik,KTH Royal Inst Technol, Sch Engn Sci, Dept Appl Phys, S-10691 Stockholm, Sweden.4 aut0 (Swepub:kth)u1oohxvn |
245 | 1 0 | a Multi-marker profiling of extracellular vesicles using streaming current and sequential electrostatic labeling |
264 | 1 | b Elsevier BV,c 2023 |
338 | a print2 rdacarrier | |
500 | a QC 20230403 | |
520 | a High heterogeneity in the membrane protein expression of small extracellular vesicles (sEVs) means that bulk methods relying on antibody-based capture for expression analysis have a drawback that each type of antibody may capture a different sub-population. An improved approach is to capture a representative sEV population, without any bias, and then perform a multiplexed protein expression analysis on this population. However, such a possibility has been largely limited to fluorescence-based methods. Here, we present a novel electrostatic labelling strategy and a microchip-based all-electric method for membrane protein analysis of sEVs. The method allows us to profile multiple surface proteins on the captured sEVs using alternating charge labels. It also permits the comparison of expression levels in different sEV-subtypes. The proof of concept was tested by capturing sEVs both non-specifically (unbiased) as well as via anti-CD9 capture probes (biased), and then profiling the expression levels of various surface proteins using the charge labelled antibodies. The method is the first of its kind, demonstrating an all-electrical and microchip based method that allows for unbiased analysis of sEV membrane protein expression, comparison of expression levels in different sEV subsets, and fractional estimation of different sEV sub-populations. These results were also validated in parallel using a single-sEV fluorescence technique. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Medicinska och farmaceutiska grundvetenskaperx Cell- och molekylärbiologi0 (SwePub)301082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Basic Medicinex Cell and Molecular Biology0 (SwePub)301082 hsv//eng |
653 | a Biosensors | |
653 | a Extracellular vesicles | |
653 | a Streaming current | |
653 | a Electrostatic labels | |
653 | a Microfluidics | |
700 | 1 | a Talebian Gevari, Moeinu Uppsala universitet,Fasta tillståndets elektronik4 aut0 (Swepub:uu)moeta494 |
700 | 1 | a Nagy, Abelu KTH,Proteinvetenskap,KTH Royal Inst Technol, Sch Chem Biotechnol & Hlth CBH, Dept Prot Sci, Stockholm, Sweden.4 aut0 (Swepub:kth)u1kg1ew9 |
700 | 1 | a Gestin, Maxime,d 1990-u KTH,Proteinvetenskap,KTH Royal Inst Technol, Sch Chem Biotechnol & Hlth CBH, Dept Prot Sci, Stockholm, Sweden.4 aut0 (Swepub:kth)u18nn0n1 |
700 | 1 | a Haag, Petrau Karolinska Institutet4 aut |
700 | 1 | a Lewensohn, Rolfu Karolinska Inst, Dept Oncol Pathol, S-17164 Stockholm, Sweden.;Karolinska Univ Hosp, Thorac Oncol Ctr, Med Unit Head & Neck Lung & Skin Tumors, Theme Canc, S-17164 Solna, Sweden.4 aut |
700 | 1 | a Viktorsson, Kristinau Karolinska Institutet4 aut |
700 | 1 | a Eriksson Karlström, Amelieu KTH,Proteinvetenskap,KTH Royal Inst Technol, Sch Chem Biotechnol & Hlth CBH, Dept Prot Sci, Stockholm, Sweden.4 aut0 (Swepub:kth)u10x6l4n |
700 | 1 | a Dev, Apurbau Uppsala universitet,KTH,Tillämpad fysik,Uppsala Univ, Dept Elect Engn, Div Solid State Elect, S-75121 Uppsala, Sweden.,Fasta tillståndets elektronik,KTH Royal Inst Technol, Sch Engn Sci, Dept Appl Phys, S-10691 Stockholm, Sweden.4 aut0 (Swepub:uu)apude110 |
710 | 2 | a KTHb Tillämpad fysik4 org |
773 | 0 | t Biosensors & bioelectronicsd : Elsevier BVg 227q 227x 0956-5663x 1873-4235 |
856 | 4 | u https://doi.org/10.1016/j.bios.2023.115142y Fulltext |
856 | 4 | u https://uu.diva-portal.org/smash/get/diva2:1751773/FULLTEXT01.pdfx primaryx Raw objecty fulltext:print |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-325236 |
856 | 4 8 | u https://doi.org/10.1016/j.bios.2023.115142 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-500017 |
856 | 4 8 | u http://kipublications.ki.se/Default.aspx?queryparsed=id:152073271 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.