Fracture of porcine aorta. Part 2: FEM modelling and inverse parameter identification

Alloisio, Marta (författare)
KTH,Hållfasthetslära
Gasser, T. Christian (författare)
KTH,Hållfasthetslära
 (creator_code:org_t)
Acta Materialia Inc, 2023
2023
Engelska.
Ingår i: Acta Biomaterialia. - : Acta Materialia Inc. - 1742-7061 .- 1878-7568. ; 167, s. 158-170
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The mechanics of vascular tissue, particularly its fracture properties, are crucial in the onset and progression of vascular diseases. Vascular tissue properties are complex, and the identification of fracture mechanical properties relies on robust and efficient numerical tools. In this study, we propose a parameter identification pipeline to extract tissue properties from force-displacement and digital image correlation (DIC) data. The data has been acquired by symconCT testing porcine aorta wall specimens. Vascular tissue is modelled as a non-linear viscoelastic isotropic solid, and an isotropic cohesive zone model describes tissue fracture. The model closely replicated the experimental observations and identified the fracture energies of 1.57±0.82 kJ m−2 and 0.96±0.34 kJ m−2 for rupturing the porcine aortic media along the circumferential and axial directions, respectively. The identified strength was always below 350 kPa, a value significantly lower than identified through classical protocols, such as simple tension, and sheds new light on the resilience of the aorta. Further refinements to the model, such as considering rate effects in the fracture process zone and tissue anisotropy, could have improved the simulation results. Statement of significance: This paper identified porcine aorta's biomechanical properties using data acquired through a previously developed experimental protocol, the symmetry-constraint compact tension test. An implicit finite element method model mimicked the test, and a two-step approach identified the material's elastic and fracture properties directly from force-displacement curves and digital image correlation-based strain measurements. Our findings show a lower strength of the abdominal aorta as compared to the literature, which may have significant implications for the clinical evaluation of the risk of aortic rupture.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Teknisk mekanik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Applied Mechanics (hsv//eng)

Nyckelord

Aorta
Cohesive zone model
Constitutive modelling
Fracture

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Alloisio, Marta
Gasser, T. Chris ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Teknisk mekanik
Artiklar i publikationen
Acta Biomaterial ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy