Imaging with multi-prism x-ray lenses
- Artikel/kapitelEngelska2008
Förlag, utgivningsår, omfång ...
-
SPIE,2008
-
printrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:kth-38399
-
https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-38399URI
-
https://doi.org/10.1117/12.770434DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:kon swepub-publicationtype
Anmärkningar
-
QC 20210120
-
The multi-prism lens (MPL) is a refractive x-ray lens consisting of two rows of prisms facing each other at an angle. Rays entering the lens at the periphery will encounter a larger number of prisms than will central ones, hence experiencing a greater refraction. The focusing effect of the MPL can be used to gather radiation from a large aperture onto a smaller detector, and accordingly to make better use of the available x-ray flux in medical x-ray imaging. Potential advantages of a better photon economy include shorter acquisition times, a reduced tube loading, or an improved resolution. Since the focusing effect is one-dimensional it matches the design of scanning systems. In this study we present the first images acquired with an MPL instead of the pre-breast slit collimator in a scanning mammography system. According to the measurements, the MPL is able to increase the flux 32% at equal resolution compared to the slit collimator, or to improve the resolution 2.4 mm(-1) at equal flux. If used with a custom-made absorption filter in a clinical set-up, the gain of flux of the MPL is expected to be at least 45%, and the corresponding improvement in resolution to be 3 mm(-1).
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Cederström, BjörnKTH,Medicinsk bildfysik,Albanova VinnExcellence Center for Protein Technology, ProNova(Swepub:kth)u1oerth9
(författare)
-
Åslund, Magnus
(författare)
-
Nillius, PeterKTH,Medicinsk bildfysik,Albanova VinnExcellence Center for Protein Technology, ProNova(Swepub:kth)u1mhl6dq
(författare)
-
Lundqvist, Mats
(författare)
-
Danielsson, MatsKTH,Medicinsk bildfysik,Albanova VinnExcellence Center for Protein Technology, ProNova(Swepub:kth)u1m3qe0f
(författare)
-
KTHMedicinsk bildfysik
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Medical Imaging 2008 - Physics of Medical Imaging: SPIE, s. 91308-913089780819470973
Internetlänk
Hitta via bibliotek
Till lärosätets databas