Optimization of operating conditions in photon counting multi-slit mammography based on Si-strip detectors - art. no. 61420A

  • Artikel/kapitelEngelska2006

Förlag, utgivningsår, omfång ...

  • SPIE,2006
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-41967
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-41967URI
  • https://doi.org/10.1117/12.652728DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:kon swepub-publicationtype

Anmärkningar

  • QC 20111004
  • Measurements and simulations of the signal-difference-to-noise ratio (SDNR) and average glandular dose (AGD) have been performed on a photon counting full-field digital mammography system to determine the optimal operating conditions. Several beam qualities were experimentally evaluated by using different combinations of tube voltage, added filters and thickness of BR12 with a tungsten target x-ray tube. The SDNR and AGD were also calculated theoretically for an extended number of operating conditions and a more accurate breast model. As figure of merit for each operating condition, a spectral quantum efficiency (SQE) was calculated as the polychromatic SDNR squared over the optimal monochromatic SDNR squared at the same AGD. The theoretical model agreed within 4% relative the measured SDNR throughout the evaluated breast thickness (30-70 mm) and tube voltage range (26-38 kV). The optimization was performed with a constant SDNR-rate as compared to using a fixed filter thickness. The optimal combinations of tube voltage-filter material were: 32 kV-Ag, 34 kV-Cd, 36 kV-Sn for a breast thickness of 30, 50 and 70 mm respectively. These K-edge filter materials increased the SQE by less than 4% compared to the optimal Al filtration.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Cederström, BjörnKTH,Fysik(Swepub:kth)u1oerth9 (författare)
  • Lundqvist, Mats (författare)
  • Danielsson, MatsKTH,Fysik(Swepub:kth)u1m3qe0f (författare)
  • KTHFysik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3: SPIE, s. A1420-A14209780819461858

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy