SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-55269"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-55269" > Spherical aberratio...

Spherical aberration in relation to visual performance in contact lens wear

Pettersson, A. Lindskoog (författare)
Karolinska Institutet
Mårtensson, L. (författare)
Salkic, J. (författare)
visa fler...
Unsbo, Peter (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Brautaset, R. (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
Elsevier BV, 2011
2011
Engelska.
Ingår i: Contact lens & anterior eye. - : Elsevier BV. - 1367-0484 .- 1476-5411. ; 34:1, s. 12-16
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction: The aim of the present study was to evaluate changes in spherical aberration and their effect on visual quality (visual acuity and contrast sensitivity) in both distance and near with different non-custom-made contact lenses. Methods: A wavefront analyser was used to measure the aberrations in each subject's eyes uncorrected and with the contact lenses: a standard lens and two aspherical contact lenses. High-contrast visual acuity at distance was measured with Test-Chart 2000(100% contrast) and at near with Sloan ETDRS Near Point chart (100% contrast). Low-contrast visual acuity at distance was measured with Test-Chart 2000 (10% contrast) and contrast measurements at near with Mars letter contrast sensitivity chart. Results: Mean spherical aberration was positive for all pupil sizes in the uncorrected eye, residual spherical aberration was close to zero with the standard lens for all pupil sizes, whereas the two aspheric contact lenses over-corrected spherical aberration. The changes in aberration were statistically significant (p < 0.05) with all lenses. No significant difference could be detected between trial frame correction, spherical and aspherical soft contact lens designs with respect to visual quality. This was the case for both distance and near. Conclusion: The results are in line with previous studies and indicate that non-custom-made spherical aberration control contact lenses have little effect on visual quality as defined in this study.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Nyckelord

Spherical aberration
Contact lenses
Aberration control
Daily disposable
Visual acuity
Contrast sensitivity

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy