Electrochemical evaluation of troponin T imprinted polymer receptor

Karimian, Najmeh (författare)
Linköpings universitet,Biosensorer och bioelektronik,Tekniska högskolan,Ferdowsi University of Mashhad, Mashhad, Iran
Turner, Anthony P.F. (författare)
Linköpings universitet,Biosensorer och bioelektronik,Tekniska högskolan
Tiwari, Ashutosh (författare)
Linköpings universitet,Biosensorer och bioelektronik,Tekniska högskolan
 (creator_code:org_t)
USA : Elsevier, 2014
2014
Engelska.
Ingår i: Biosensors & bioelectronics. - USA : Elsevier. - 0956-5663 .- 1873-4235. ; 59, s. 160-165
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The selective detection and quantification of macromolecular targets is a fundamental biological mechanism in nature. Molecularly imprinted polymers (MIPs) have been identified as one of the most promising synthetic alternatives to bioreceptors. However, expanding this methodology towards selective recognition of bulky templates such as proteins appears to be extremely challenging due to problems associated with removal of the template from the polymeric network. In this study, polymer imprinted with troponin T (TnT) was assessed using electrochemical methods and the influence of various extraction methods, including conventional immersion extraction, thermal annealing and ultrasonic-assisted extraction, on the binding characteristics of the troponin-to-imprinted polymer receptor was elucidated. Cyclic voltammetric deposition of o-phenylenediamine (o-PD) film in the presence of TnT as a template was performed in acetate buffer (0.5 M, pH 5.2) on a gold substrate. Solvent extraction of the target molecule was optimised and followed by subsequent washing with water. The electrochemistry of a ferro/ferricyanide probe was used to characterise the TnT MIP receptor film. The incubation of the TnT MIP receptor-modified electrode with respect to TnT concentration resulted in a suppression of the ferro/ferricyanide redox current. The dissociation constant (KD) was calculated using a two-site model of template affinity for the TnT MIP receptor. The synthetic TnT MIP receptor had high affinity for TnT with a KD of 2.3×10−13 M.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk material- och protesteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Materials (hsv//eng)

Nyckelord

Synthetic receptor; Imprinted polymer; Troponin T; Template affinity; Electrochemical study

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Karimian, Najmeh
Turner, Anthony ...
Tiwari, Ashutosh
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk materi ...
Artiklar i publikationen
Biosensors & bio ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy