Sökning: onr:"swepub:oai:DiVA.org:liu-132860" >
Blood flow response...
Blood flow responses over sacrum in nursing home residents during one hour bed rest
-
- Källman, Ulrika (författare)
- Linköpings universitet,Avdelningen för omvårdnad,Medicinska fakulteten,Södra Älvsborgs Sjukhus, Sweden
-
- Bergstrand, Sara (författare)
- Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska fakulteten
-
- Ek, Anna-Christina (författare)
- Linköpings universitet,Avdelningen för omvårdnad,Medicinska fakulteten,Region Östergötland, Akutkliniken i Linköping
-
visa fler...
-
- Engström, Maria (författare)
- Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
-
- Lindgren, Margareta (författare)
- Linköpings universitet,Medicinska fakulteten,Avdelningen för omvårdnad
-
visa färre...
-
(creator_code:org_t)
- 2016-10-27
- 2016
- Engelska.
-
Ingår i: Microcirculation. - : WILEY-BLACKWELL. - 1073-9688 .- 1549-8719. ; 23:7, s. 530-539
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- ObjectivesTo describe individual BF responses in a nursing home resident population for one-hour periods of bed rest. MethodsBF was measured for one hour over the sacrum in 0 degrees supine position and 30 degrees supine tilt position in 25 individuals aged 65 y or older while lying on a pressure-redistributing mattress. Measurements were made at three tissue depths (1, 2, and 10 mm) using the noninvasive optical techniques, LDF and PPG. ResultsEleven participants had a PIV response at 1mm depth in both positions and seven participants had a lack of this response at this depth and positions. The BF response at 1mm depth appeared immediately and remained over, or below, baseline for the entire 60min of loading in both positions. These BF patterns were also seen in deeper tissue layers. ConclusionsThe cutaneous BF response among the nursing home residents was distinct, appeared early, and remained during the one hour of loading.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Physiology (hsv//eng)
Nyckelord
- immobility; interface pressure; nursing home residents; pressure-induced vasodilation; tissue blood flow
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas