SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-133258"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-133258" > Increased fMRI Sens...

Increased fMRI Sensitivity at Equal Data Burden Using Averaged Shifted Echo Acquisition

Witt, Suzanne (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Warntjes, Marcel Jan Bertus (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
Engström, Maria (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
 (creator_code:org_t)
2016-11-23
2016
Engelska.
Ingår i: Frontiers in Neuroscience. - : FRONTIERS MEDIA SA. - 1662-4548 .- 1662-453X. ; 10
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • There is growing evidence as to the benefits of collecting BOLD fMRI data with increased sampling rates. However, many of the newly developed acquisition techniques developed to collect BOLD data with ultra-short TRs require hardware, software, and non-standard analytic pipelines that may not be accessible to all researchers. We propose to incorporate the method of shifted echo into a standard multi-slice, gradient echo EPI sequence to achieve a higher sampling rate with a TR of amp;lt; 1 s with acceptable spatial resolution. We further propose to incorporate temporal averaging of consecutively acquired EPI volumes to both ameliorate the reduced temporal signal-to-noise inherent in ultra-fast EPI sequences and reduce the data burden. BOLD data were collected from 11 healthy subjects performing a simple, event-related visual-motor task with four different EPI sequences: (1) reference EP/sequence with TR = 1440 ms, (2) shifted echo EP/sequence with TR = 700 ms, (3) shifted echo EPI sequence with every two consecutively acquired EPI volumes averaged and effective TR = 1400 ms, and (4) shifted echo EPI sequence with every four consecutively acquired EPI volumes averaged and effective TR = 2800 ms. Both the temporally averaged sequences exhibited increased temporal signal-to-noise over the shifted echo EPI sequence. The shifted echo sequence with every two EPI volumes averaged also had significantly increased BOLD signal change compared with the other three sequences, while the shifted echo sequence with every four EPI volumes averaged had significantly decreased BOLD signal change compared with the other three sequences. The results indicated that incorporating the method of shifted echo into a standard multi-slice EPI sequence is a viable method for achieving increased sampling rate for collecting event-related BOLD data. Further, consecutively averaging every two consecutively acquired EPI volumes significantly increased the measured BOLD signal change and the subsequently calculated activation map statistics.

Ämnesord

SAMHÄLLSVETENSKAP  -- Psykologi -- Psykologi (hsv//swe)
SOCIAL SCIENCES  -- Psychology -- Psychology (hsv//eng)

Nyckelord

fMRI; shifted echo; sampling rate; fast imaging; BOLD; EPI; temporal averaging; data burden

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Witt, Suzanne
Warntjes, Marcel ...
Engström, Maria
Om ämnet
SAMHÄLLSVETENSKAP
SAMHÄLLSVETENSKA ...
och Psykologi
och Psykologi
Artiklar i publikationen
Frontiers in Neu ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy