Fixed volume particle trace emission for the analysis of left atrial blood flow using 4D Flow MRI

Gaeta, Stephen (författare)
Duke Univ, NC USA
Dyverfeldt, Petter (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
Eriksson, Jonatan (författare)
Linköpings universitet,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Avdelningen för kardiovaskulär medicin
visa fler...
Carlhäll, Carljohan (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
Ebbers, Tino (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
Bolger, Ann F (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Region Östergötland, Fysiologiska kliniken US,Univ Calif San Francisco, CA 94143 USA
visa färre...
 (creator_code:org_t)
ELSEVIER SCIENCE INC, 2018
2018
Engelska.
Ingår i: Magnetic Resonance Imaging. - : ELSEVIER SCIENCE INC. - 0730-725X .- 1873-5894. ; 47, s. 83-88
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • 4D Flow MRI has been used to quantify normal and deranged left ventricular blood flow characteristics on the basis of functionally distinct flow components. However, the application of this technique to the atria is challenging due to the presence of continuous inflow. This continuous inflow necessitates plane-based emission of particle traces from the inlet veins, leading to particles that represents different amounts of blood, and related quantification errors. The purpose of this study was to develop a novel fixed-volume approach for particle tracing and employ this method to develop quantitative analysis of 4D blood flow characteristics in the left atrium. 4D Flow MRI data were acquired during free-breathing using a navigator-gated gradient-echo sequence in three volunteers at 1.5 T. Fixed-volume particle traces emitted from the pulmonary veins were used to visualize left atrial blood flow and to quantitatively separate the flow into two functionally distinct flow components: Direct flow = particle traces that enter and leave the atrium in one heartbeat, Retained flow = particle traces that enter the atrium and remains there for one cardiac cycle. Flow visualization based on fixed-volume traces revealed that, beginning in early ventricular systole, flow enters the atrium and engages with residual blood volume to form a vortex. In early diastole during early ventricular filling, the organized vortical flow is extinguished, followed by formation of a second transient atrial vortex. Finally, in late diastole during atrial contraction, a second acceleration of blood into the ventricle is seen. The direct and retained left atrial flow components were between 44 and 57% and 43-56% of the stroke volume, respectively. In conclusion, fixed volume particle tracing permits separation of left atrial blood flow into different components based on the transit of blood through the atrium.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

4D Flow MRI; MR Flow Imaging; Left atrium; Blood flow; Cardiovascular disease; Cardiovascular physiology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy