SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-162875"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-162875" > Comparability of ac...

Comparability of accelerometer signal aggregation metrics across placements and dominant wrist cut points for the assessment of physical activity in adults

Migueles, Jairo H. (författare)
Univ Granada, Spain
Cadenas-Sanchez, Cristina (författare)
Univ Granada, Spain
Rowlands, Alex V. (författare)
Univ Leicester, England; NIHR Leicester Biomed Res Ctr, England; Univ South Australia, Australia
visa fler...
Henriksson, Pontus (författare)
Linköpings universitet,Avdelningen för samhällsmedicin,Medicinska fakulteten,Univ Granada, Spain; Karolinska Inst, Sweden
Shiroma, Eric J. (författare)
NIA, MD 20892 USA
Acosta, Francisco M. (författare)
Univ Granada, Spain
Rodriguez-Ayllon, Maria (författare)
Univ Granada, Spain
Esteban-Cornejo, Irene (författare)
Univ Granada, Spain; Northeastern Univ, MA 02115 USA
Plaza-Florido, Abel (författare)
Univ Granada, Spain
Gil-Cosano, Jose J. (författare)
Univ Granada, Spain
Ekelund, Ulf (författare)
Norwegian Sch Sport Sci, Norway
van Hees, Vincent T. (författare)
Netherlands eSci Ctr, Netherlands
Ortega, Francisco B. (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2019-12-03
2019
Engelska.
Ingår i: Scientific Reports. - : NATURE PUBLISHING GROUP. - 2045-2322. ; 9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Large epidemiological studies that use accelerometers for physical behavior and sleep assessment differ in the location of the accelerometer attachment and the signal aggregation metric chosen. This study aimed to assess the comparability of acceleration metrics between commonly-used body-attachment locations for 24 hours, waking and sleeping hours, and to test comparability of PA cut points between dominant and non-dominant wrist. Forty-five young adults (23 women, 18-41 years) were included and GT3X + accelerometers (ActiGraph, Pensacola, FL, USA) were placed on their right hip, dominant, and non-dominant wrist for 7 days. We derived Euclidean Norm Minus One g (ENMO), Low-pass filtered ENMO (LFENMO), Mean Amplitude Deviation (MAD) and ActiGraph activity counts over 5-second epochs from the raw accelerations. Metric values were compared using a correlation analysis, and by plotting the differences by time of the day. Cut points for the dominant wrist were derived using Lins concordance correlation coefficient optimization in a grid of possible thresholds, using the nondominant wrist estimates as reference. They were cross-validated in a separate sample (N = 36, 10 women, 22-30 years). Shared variances between pairs of acceleration metrics varied across sites and metric pairs (range in r(2) : 0.19-0.97, all p amp;lt; 0.01), suggesting that some sites and metrics are associated, and others are not. We observed higher metric values in dominant vs. non-dominant wrist, thus, we developed cut points for dominant wrist based on ENMO to classify sedentary time (amp;lt;50 mg), light PA (50-110 mg), moderate PA (110-440 mg) and vigorous PA (amp;gt;= 440 mg). Our findings suggest differences between dominant and non-dominant wrist, and we proposed new cut points to attenuate these differences. ENMO and LFENMO were the most similar metrics, and they showed good comparability with MAD. However, counts were not comparable with ENMO, LFENMO and MAD.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy