Sökning: onr:"swepub:oai:DiVA.org:liu-165098" >
The Oticon Medical ...
The Oticon Medical Neuro Zti cochlear implant and the Neuro 2 sound processor: multicentric evaluation of outcomes in adults and children
-
- Franco-Vidal, Valerie (författare)
- Bordeaux Univ Hosp, France
-
- Parietti-Winkler, Cecile (författare)
- Cent Univ Hosp, France
-
- Guevara, Nicolas (författare)
- Univ Cote DAzur, France
-
visa fler...
-
- Truy, Eric (författare)
- Lyon Univ Hosp, France
-
- Loundon, Natalie (författare)
- Necker Univ Hosp Sick Children, France
-
- Bailleux, Sonanda (författare)
- Nice Lenval Univ Hosp, France
-
- Ardoint, Marine (författare)
- Oticon Med, France
-
- Saai, Sonia (författare)
- Oticon Med, France
-
- Hoen, Michel (författare)
- Oticon Med, France
-
- Laplante-Lévesque, Ariane (författare)
- Linköpings universitet,Handikappvetenskap,Filosofiska fakulteten,Oticon Med, Denmark
-
- Mosnier, Isabelle (författare)
- Pitie Salpetriere Univ Hosp, France
-
- Bordure, Philippe (författare)
- Nantes Univ Hosp, France
-
- Vincent, Christophe (författare)
- Lille Univ Hosp, France
-
visa färre...
-
(creator_code:org_t)
- 2019-10-04
- 2020
- Engelska.
-
Ingår i: International Journal of Audiology. - : TAYLOR & FRANCIS LTD. - 1499-2027 .- 1708-8186. ; 59:2, s. 153-160
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
https://www.tandfonl...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective: This study evaluated the outcomes of the Oticon Medical Neuro Zti cochlear implant and the Neuro 2 sound processor. Design: Neuro One users were upgraded to Neuro 2. Monosyllabic word identification was evaluated in adults with Neuro One after >= 5 months, with Neuro 2 at upgrade, and with Neuro 2 after 3 months. Self-reported listening ability, satisfaction, and usability were measured in adults and children. Study sample: Participants were 44 adults and 26 children. Results: Speech identification scores in quiet and noise were 58% and 45% with Neuro One and 67% and 55% with Neuro 2 after 3 months, respectively. Hearing impairment duration and number of active electrodes significantly predicted speech identification in noise with Neuro 2. Significantly higher questionnaire ratings were obtained for Neuro 2 than Neuro One regarding listening ability in complex listening situations, comfort and music, as well as nine aspects of satisfaction and usability. Conclusion: This study demonstrates the clinical superiority of the Neuro 2 sound processor over Neuro One in terms of speech identification in quiet and in noise and reported patient benefit and satisfaction. Given the study design, sources of improvement may include factors unrelated to the sound processor itself.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Oto-rhino-laryngologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Otorhinolaryngology (hsv//eng)
Nyckelord
- Oticon Medical Neuro Zti and Neuro 2; cochlear implantation; sound processor; speech perception
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Franco-Vidal, Va ...
-
Parietti-Winkler ...
-
Guevara, Nicolas
-
Truy, Eric
-
Loundon, Natalie
-
Bailleux, Sonand ...
-
visa fler...
-
Ardoint, Marine
-
Saai, Sonia
-
Hoen, Michel
-
Laplante-Lévesqu ...
-
Mosnier, Isabell ...
-
Bordure, Philipp ...
-
Vincent, Christo ...
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Oto rhino laryng ...
- Artiklar i publikationen
-
International Jo ...
- Av lärosätet
-
Linköpings universitet