Sökning: onr:"swepub:oai:DiVA.org:liu-165483" >
Correlation-Based C...
Correlation-Based Calibration for Nonlinearity Mismatches in Dual-Channel TIADCs
-
- Liu, Xiangyu (författare)
- Natl Univ Def Technol, Peoples R China
-
- Xu, Hui (författare)
- Natl Univ Def Technol, Peoples R China
-
- Johansson, Håkan (författare)
- Linköpings universitet,Kommunikationssystem,Tekniska fakulteten
-
visa fler...
-
- Wang, Yinan (författare)
- Natl Univ Def Technol, Peoples R China
-
- Li, Nan (författare)
- Natl Univ Def Technol, Peoples R China
-
visa färre...
-
(creator_code:org_t)
- IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2020
- 2020
- Engelska.
-
Ingår i: IEEE Transactions on Circuits and Systems - II - Express Briefs. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 1549-7747 .- 1558-3791. ; 67:3, s. 585-589
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Mismatches affect the dynamic performance of time-interleaved analog-to-digital converters (TIADCs). Linear mismatches can be calibrated by many mature methods, but if higher performance is required, nonlinearity mismatches have to be suppressed. The background calibration method based on input-free band (IFB) functions poorly for narrow-band signals. This brief proposes a correlation-based calibration method for nonlinearity mismatches in dual-channel TIADCs which behaves well for both wide-band and narrow-band signals. The output samples are calibrated by reducing the residual distortions which are approximated by multiplying the pseudo distortions and the estimated mismatch coefficients. The pseudo distortions are acquired by using a frequency-shifter, a differentiator, and multipliers. The coefficients which indicate the mismatch strength are estimated by eliminating the cross-correlation of the calibrated output samples and the calibrated pseudo distortions at zero lag. Simulations show that the proposed method can improve the SFDR by dozens of dBc for narrow-band input signals, compared with the IFB method. For the 16-QAM signal, the error vector magnitude improvement over the IFB method is 35.48 dB.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)
Nyckelord
- Estimation; Calibration; Nonlinear distortion; Integrated circuit modeling; Buffer storage; Time-interleaved (TI); analog-to-digital converter (ADC); nonlinearity mismatches; calibration; correlation; background estimation
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas