Objective assessment of skin microcirculation using a smartphone camera

Tesselaar, Erik (författare)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Medicinsk strålningsfysik
Farnebo, Simon (författare)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Hand- och plastikkirurgiska kliniken US
 (creator_code:org_t)
2020-07-15
2021
Engelska.
Ingår i: Skin research and technology. - : WILEY. - 0909-752X .- 1600-0846. ; 27:2, s. 138-144
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background Existing techniques for assessment of microcirculation are limited by their large size and high costs and are often not so easy to use. Advances in mobile technology have enabled great improvements in smartphone sensor technology. In this study, we used SkinSight, an app for iPhone and iPad, to measure changes in skin microcirculation during physiological provocations. The system estimates changes in the concentration of hemoglobin in the skin by analyzing the reflected light emitted from the built-in light-emitting diode and detected by the camera of the smartphone. Methods A relative hemoglobin (Hb) index was measured during a 5-min arterial occlusion, post-occlusive reactive hyperemia, and a 5-min venous occlusion in 10 healthy subjects, on two separate days. The index was calculated in an area of the skin from the color information in the images acquired by the phone camera. Polarized light spectroscopy imaging was used to measure changes in red blood cell concentration for comparison. Results During arterial occlusion, relative Hb index was unchanged compared to baseline (P= .40). After release of the cuff, a sudden 60%-75% increase in Hb index was observed (P< .001) followed by a gradual return to baseline. During venous occlusion, Hb index increased by 80% (P< .001) followed by a gradual decrease to baseline after reperfusion. Day-to-day reproducibility of the relative Hb index was excellent (ICC: 0.92, r = 0.94), although relative Hb index was consistently higher during the second day, possibly as a result of changed lighting conditions or calibration issues. Conclusion Microvascular responses to physiological provocations in the skin can be accurately and reproducibly measured using a smartphone application. Although the system offers a handheld, easy to use and flexible technique for skin microvascular assessment, the effects of lighting on the measured values and need for calibration need to be further investigated.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

hemoglobin; microcirculation; post-occlusive reactive hyperemia; smartphone; venous occlusion

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Tesselaar, Erik
Farnebo, Simon
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
Artiklar i publikationen
Skin research an ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy