Estimation of skin microcirculatory hemoglobinoxygen saturation and red blood cell tissue fractionusing a multispectral snapshot imaging system : a validation study

Ewerlöf, Maria, 1987- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
Salerud, Göran, 1954- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
Strömberg, Tomas, 1966- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
visa fler...
Larsson, Marcus, 1974- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
visa färre...
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2021
2021
Engelska.
Ingår i: Journal of Biomedical Optics. - : SPIE - International Society for Optical Engineering. - 1083-3668 .- 1560-2281. ; 26:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Significance: Hemoglobin oxygen saturation and red blood cell (RBC) tissue fraction are important parameters when assessing microvascular status. Functional information can be attained using temporally resolved measurements performed during stimulus–response protocols. Pointwise assessments can currently be conducted with probe-based systems. However, snapshot multispectral imaging (MSI) can be used for spatial–temporal measurements.Aim: To validate if hemoglobin oxygen saturation and RBC tissue fraction can be quantified using a snapshot MSI system and an inverse Monte Carlo algorithm.Approach: Skin tissue measurements from the MSI system were compared to those from a validated probe-based system during arterial and venous occlusion provocation on 24 subjects in the wavelength interval 450 to 650 nm, to evaluate a wide range of hemoglobin oxygen saturation and RBC tissue fraction levels.Results: Arterial occlusion results show a mean linear regression R2 = 0.958 for hemoglobin oxygen saturation. Comparing relative RBC tissue fraction during venous occlusion results in R2 = 0.925. The MSI system shows larger dynamic changes than the reference system, which might be explained by a deeper sampling including more capacitance vessels.Conclusions: The snapshot MSI system estimates hemoglobin oxygen saturation and RBC tissue fraction in skin microcirculation showing a high correlation (R2 > 0.9 in most subjects) with those measured by the reference method.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

multispectral imaging
hemoglobin oxygen saturation
RBC tissue fraction
diffuse reflectance spectroscopy
Monte Carlo simulations
skin microcirculation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy